7
Wire Connections
Wiring:
Splice to Circuit Board (CB) (For 900, 9100, N600, N800 Models):
- Route the 6” red spliced wire and attached 60” red fused wire between the front and back
absorber coils (Figure 2).
- Connect the female end of the 6” red spliced wire to the +12 V CB (circuit board) terminal
(Figure 7).
- Route the 6” black spliced wire and attached 24” black wire between the front and back
absorber coils (Figure 2).
- Connect the female end of the 6” black spliced wire to the 12 VCOM CB ground terminal
(Figure 7).
- Secure all wires so they do not contact hot surfaces or sharp edges on the condenser fins or
absorber coils. Use cable ties and adhesive mounting plates (figure 2) as described below.
- Use a cable tie to secure the 41” red wire, the 6” red wire, and the 24” black wire to the
pressure relief valve (Figure 5).