Condenser Slant-Figure 30
Important:
When installing the cooling unit, do not install the screw
holding the condenser until the condenser slant is
checked. With the refrigerator in a level position, draw
a level line starting at the top left corner of the con-
denser, as shown in Figure 30. The left side of the
condenser can be raised or lowered slightly to obtain
the "A" dimension. Install screw to tab to maintain "A"
dimension.
Refrigerator Leveling Tool-Figure 31
This is a handy tool to insure that the refrigerator does
not exceed 3" off-level. Make a wooden block which
very accurately conforms to the dimensions shown.
The thickness is not important (1" for example) but the
top and bottom surfaces must be smooth and straight.
Set (or attach) an accurate torpedo type level on the
block as shown.
Check for level as follows:
Set the level assembly on a flat surface (glass shelf)
so that the ends point to the sides of the refrigerator.
Most of the bubble must be to the "A" side of the center
line. Turn the level assembly end for end. Most of the
bubble must again be to the "A" side of center line; If
not, the refrigerator is more than 3° off-level. If either
reading shows most of the bubble to the "B" side, then
the refrigerator is more than 3° off-level.
Figure 31
Condenser
Level LIne
Model "A"
Dimension
1082
3/4" Min. 1 1/4" Max.
Figure 30
22