MODEL 910130  10,000 P.S.I. CAPACITY AIR/HYDRAULIC FOOT PUMP

SETUP • OPERATING • MAINTENANCE INSTRUCTIONS

 PROFESSIONAL LIFTING EQUIPMENT

®

BEFORE  USING  THIS  DEVICE,  READ  THIS  MANUAL 

COMPLETELY  AND  THOROUGHLY,  UNDERSTAND  ITS 

OPERATING  PROCEDURES,  SAFETY  WARNINGS  AND 

MAINTENANCE REQUIREMENTS. FAILURE TO DO SO COULD 

CAUSE  ACCIDENTS  RESULTING  IN  SERIOUS  OR  FATAL 

PERSONAL INJURY AND/OR PROPERTY DAMAGE.

The use of air/hydraulic foot pumps is subject to certain hazards 
that  cannot  be  prevented  by  mechanical  means,  but  only  by  the 
exercise of intelligence, care, and common sense. It is therefore 
essential  to have owners  and  personnel  involved  in  the use  and 
operation of equipment who are careful, competent, trained, and 

qualified in the safe operation of the equipment and its proper use. 

Hazards such as pressurized hydraulic fluid bursting from hoses or 

fittings can happen resulting in loss of load, uncontrolled lowering 

or dropping of load if instructions are not followed. Failure to avoid 

hazards could cause accidents resulting in serious or fatal personal 
injury and/or property damage.

It is the responsibility of the owner to make sure all personnel read 
this manual prior to using this device. It is also the responsibility 
of  the  device  owner  to  keep  these  instructions  intact  and  in  a 
convenient  location  for  all  to  see  and  read.  If  these  instructions 
are lost or not legible, contact Norco for a free replacement. If the 

operator is not fluent in English, the product and safety instructions 

shall be read to and discussed with the operator in the operator’s 
native language by the purchaser/owner or his designee, making 
sure that the operator comprehends its contents. 

WARRANTY

This product is covered by a Limited Lifetime Warranty. For details 
see the back cover of Norco’s product catalog.

IMPORTANT: READ THESE INSTRUCTIONS BEFORE OPERATING

WARNING

Do not use hoses in systems exceeding 10,000 psi (700 bar).

• 

The system operating pressure must not exceed the pressure 

• 

rating of the lowest rated component in the system.

Avoid sharp bends and kinks when routing hydraulic hoses.

• 

Do not drop heavy objects on hose.

• 

Do not use the hydraulic hose to carry a hydraulic component.

• 

Keep hydraulic equipment away from flames and heat.

• 

Keep hose away from sharp objects and eliminate abrasion.

• 

Inspect the system before each use. Replace questionable 

• 

components immediately.

Use only compatible fluids.

• 

Make sure quick disconnect fittings are correctly and 

• 

completely fastened together. Quick disconnect couplers 
should be hand tightened only. Never use tools.

Never attempt to disconnect couplers while under system 

• 

pressure.

Be sure pressure system and setup are stable before using.

• 

BEFORE OPERATING

Remove the large allen socket pipe plug in the end of the black 

1. 

elbow fitting that is installed in the side of the foot pump manifold. 

Remove any remnants of teflon tape that may still be in the threads 

of the elbow fitting.

Determine if your system will require a poppit valve to restrict 

2. 

the  return  flow  of  oil  back  to  the  pump’s  reservoir.  Consult 

the  “OPERATING  INSTRUCTIONS”  portion  of  this  manual  to 

determine  if  your  system  requires  a  poppit  valve.  If  your  system 
does require a poppit valve, install the tapered end of the poppit 

valve into the threaded hole at the end of the elbow fitting. Make 

sure the poppit valve is inserted all the way until it bottoms out on 
the seat at the bottom of the threaded hole.

Make  sure  the  hose  fitting  threads  are  not  crossthreaded. 

3. 

Use  at  least  1-1/2  wraps  of  teflon  tape  (or  suitable  sealant)  on 

the threads. Make sure the first complete thread is free from tape 

or  sealant  so  they  do  not  enter  and  contaminate  the  hydraulic 
system.

If  tubing  is  used  instead  of  hose,  make  sure  the  tubing  is 

4. 

supported.  Unsupported  tubing  can  lead  to  premature  fitting 

failure.  Always  hard  mount  valves  and  gages  and  never  allow 
tubing to support them. Place tube supports 4 to 7 inches behind 

the fitting.

The air quick disconnect configuration of your choice can be 

5. 

installed  in  the  threaded  hole  underneath  the  foot  pedal  labeled 

“PUMP”.  Prepare  the  threaded  hole  in  the  pump  and  air  quick 

disconnect  threads  in  the  same  manner  as  described  in  steps  1 

and 3 of this section titled “BEFORE OPERATING”.

The top forward section of the pump includes an air vent stem 

6. 

which  must  be  grabbed  with  thumb  and  forefinger  and  lifted  up 

to  the  air  vent  position.  The  pump  will  not  work  to  its  maximum 

efficiency unless this air vent is opened. Close the air vent when 

not using or  transporting the pump.

An in-line filter/regulator/lubricator should be installed close to 

7. 

pump. Add a few drops of SAE 30 oil to the air intake weekly if no 

lubricator is used or when pump will be idle for a long time.

Note: Revision letters (A, B, C, D etc.) after model numbers have been omitted as they do not affect the setup,

 

operating and maintenance instructions of a particular jack unless otherwise noted.