NORBAIN HIGH RESOLUTION 1/3

WARNING

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT 
EXPOSE THIS PRODUCT TO RAIN OR MOISTURE.  DO  NOT  INSERT  

ANY  METALLIC  OBJECT  THROUGH THE VENTILATION GRILLS 

OR OTHER OPENINGS ON THE EQUIPMENT.

CAUTION

C A U T I O N

C A U T I O N

RISK OF ELECTRIC SHOCK

DO NOT OPEN

 CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
                  DO NOT REMOVE COVER(OR BACK).
                NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

EXPLANATION OF GRAPHICAL SYMBOLS

The  lightning  flash  with  arrowhead  symbol,  within  an 
equilateral  triangle,  is  intended  to  alert  the  user  to  the 
presence  of  uninsulated  "dangerous  voltage"  within  the 
product's enclosure that may be of sufficient magnitude to 
constitute a risk of electric s h o c k  t o  p e r s o n s .

The  exclamation  point  within  an  equilateral  triangle  is 
intended  to  alert  the  user  to  the  presence  of  important 
operating  and  maintenance  (servicing)  instructions  in  the 
literature accompanying the product.

Summary of Contents for HIGH RESOLUTION 1/3" CCD BLACK & WHITE

Page 1: ...3 CCD BLACK WHITE HIGH RESOLUTION 1 3 CCD COLOUR DAY NIGHT VISTA 3 AXIS VANDAL RESISTANT DOME CAMERAS Please read this manual thoroughly before use and keep it handy for future reference Installation...

Page 2: ...E ACCURATE IN ALL RESPECTS HOWEVER WE CANNOT ASSUME RESPONSIBILITY FOR ANY CONSEQUENCES RESULTING FROM THE USE THEREOF THE INFORMATION CONTAINED HEREIN IS SUBJECT TO CHANGE WITHOUT NOTICE REVISIONS OR...

Page 3: ...NSIDE REFER SERVICINGTO QUALIFIED SERVICE PERSONNEL EXPLANATION OF GRAPHICAL SYMBOLS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the prese...

Page 4: ...WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES CE COMPLIANCE STATEMENT V...

Page 5: ...ent of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where thy exit from the apparatus 11 Only use attachmen...

Page 6: ...gh quality picture 4 9mm Vari focal Lens 4 9mm vari focal DC Auto Iris Lens 4 9mm vari focal Day Night DC Auto Iris Lens 3 6mm F3 8 fixd lris Lens Allows a large area to be monitored from a single cam...

Page 7: ...mera directly into the sun 1 Lens Allows a wide area to be monitored 2 Power 24VAC input 12VDC input 3 Video BNC connector used to connect the camera to a monitor switcher etc 2 1 3 1 2 3 POWER Use Ce...

Page 8: ...2 6 6 4 9mm DC Varifocal lens for wide area monitoring 2 Power 12VDC power 2 1mm socket centre ve 3 Video BNC video output connects to monitor or accessory equipment mm DC Varifocal lens for wide area...

Page 9: ...4 TOP TOP TOP Note Arrow mark indicates the top of the camera image...

Page 10: ...INSTALLING ADJUSTING CAMERA MODULE VVRD4V9 5 Use the following drawings to install the camera module to the housing Screw Taptite FC M3x6...

Page 11: ...INSTALLING ADJUSTING CAMERA MODULE VVRD4V9 LP Use the following drawings to install the camera module to the housing Screw Taptite FC M3x6 6...

Page 12: ...INSTALLING ADJUSTING CAMERA MODULE VVRDF4V9 7 Use the following drawings to install the camera module to the housing Screw Taptite FC M3x6...

Page 13: ...ousing to the screw anchors MOUNTING HOUSING TO ELECTRICAL BOX The housing can also be mounted on a 4s electrical box The housing can also be mounted on a 2s electrical box Plastic anchors 4x Teflon T...

Page 14: ...the drilling guide label for the screw anchors Insert the screw anchors and attach the housing to the screw anchors Torx screws 4x The housing can also be mounted on a 4s electrical box by attaching i...

Page 15: ...VVRDF4V9 3 Use silicone sealant around the rubber grommet to protect it against water intrusion 4 Before closing the housing take off the protective nylon and insert the supplied desiccant bag Note Si...

Page 16: ...HEATER KIT INSTALLATION VVRD4V9 Power Supply 24V AC 12V DC Power Consumption 20W o o Heater ON at 41 F 5 C o o Heater OFF at 59 F 15 C HEATER IF APPLICABLE Camera Power Cable DC 12V AC 24V Power Cabl...

Page 17: ...Heater OFF at 59 F 15 C HEATER IF APPLICABLE HEATER KIT INSTALLATION VVRD4V9 LP Use the following drawings to install the camera the heater kit in the housing POWER Use Certified Listed Class 2 power...

Page 18: ...phase This affects auto switching of the cameras by causing a vertical flip or roll during the switch interval The vertical phase adjustment allows the camera s line lock sync to be adjusted from 0 t...

Page 19: ...EL DC AUTO IRIS LENS Image Size 1 3 CCD Focal Length Aperture Ratio Angular Field of View SPEC DIAGONAL o 4mm 92 4 o 9mm 39 2 4 0 9 0mm 5 2 6 6 0 mm 5 1 1 6 2 4 5 Black Control White Control Red Drive...

Page 20: ...ontrols backlight compensation When set to ON the camera will automatically try to maintain proper exposure in the specific area even if the lighting level changes E I on off SHTR Aes When set to the...

Page 21: ...wo white balance setting ATW auto tracing white balance The camera automatically aim to maintain white objects as white even if the light colour changes Switch Position Hi AWB auto white balance Quick...

Page 22: ...0 sec Operating Temperature Humidity o 14 F to o 122 F o 10 C to o 50 C 96 non condensing Video Signal Format NTSC 525 Lines PAL 625 Lines Resolution NTSC 480 TV Lines Colour 530 TV Lines B W PAL 480...

Page 23: ...Switch EI ON OFF Dip Switch D N Conversion Colour BW Dip Switch AGC ON OFF Dip Switch D N Mode Selection Auto Manual Dip Switch White Balance Low ATW Hi AWB Dip Switch Sync Internal Line Lock Dip Swit...

Page 24: ...ON Fixed See dimensional outline Flush Mount 1 54 lb 0 7 kg Surface Mount 1 1 76 lb 0 8 kg Surface Mount 2 1 32 lb 0 6 kg Wall or Ceiling Mount 1 54 lb 0 7 kg Corner Mount 1 65 lb 0 75 kg Ceiling Moun...

Page 25: ...Unit Shipping 2 6L x 1 65W x 1 65H in 6 5L x 4 2W x 4 2H cm Unit mm 0 118 in 3 0 mm thick Optically clear impact resistant P C 3 15 in 8 0 cm diameter Optional tinted P C PT 3 4 and PT 1 2 conduit fi...

Page 26: ...w Size Cable Entry Weight Unit Shipping 2 6L x 1 65W x 1 65H in 6 5L x 4 2W x 4 2H cm Unit mm 0 1 in 2 5mm thick impact resistant P C LEXAN 3 46 in 8 8cm diameter Two 3 4 conduit fitting for NPT threa...

Page 27: ...y Weight Unit Shipping 2 6L x 1 65W x 1 65H in 6 5L x 4 2W x 4 2H cm Unit mm 0 118 in 3 0mm thick Optically clear impact resistant LEXAN 3 15 in 8 0cm diameter Optional tinted LEXAN Two 0 3 0 8cm open...

Page 28: ...302028B PRINTED IN KOREA Norbain SDL Limited Norbain SDL Norbain House Eskdale Road Winnersh Triangle Wokingham Berkshire RG41 5TS England Tel 44 0 118 912 5000 Fax 44 0 118 944 0999 www vista cctv co...