14
6.6
Main Lift Sensor Installation
Figure 11: Main Lift Bracket Assembly
1.
There are a variety of ways to mount the main lift bracket on most sprayers. The bracket
should position the sensor approximately in the center of the sprayer, forward of the
boom. An example of this mounting is illustrated in
Figure 12
.
2.
Mount the ultrasonic sensor to the main lift bracket. Run the sensor cable down the center
of the main lift bracket tube.
Figure 12: Example Mounting of the Main Lift Bracket
Avoid mounting the main lift sensor over or near a wheel-track. Measurements
from the wheel-track do not provide an accurate crop height and will cause
measurement and control error.
Ensure the bracket does not collide with any other part of the sprayer throughout
the full range of main lift motion.
Summary of Contents for UCB Sx275
Page 1: ...Versatile Sx275 Installation Manual VS01 ...
Page 7: ...4 4 Kit Parts 4 1 Kit Overview Figure 2 VS01 System Parts ...
Page 8: ...5 4 2 Hydraulic Plumbing Figure 3 VS01 Hydraulic Plumbing ...
Page 32: ...29 12 5 ITEM C10 43230 04 CABLE UC5 VALVE DT TO DT ...
Page 33: ...30 12 6 ITEM C20 43240 01 CABLE UC5 INTERFACE TILT DT ...
Page 34: ...31 12 7 ITEM C21 43240 07 CABLE UC5 INTERFACE MAIN DT WITH AUX 1 2 ...
Page 35: ...32 12 8 ITEM C30 43250 04 CABLE UC5 BATTERY AMP FUSED 5A ...