background image

 

 
 
 

11

6.5

 

Nitro Bracket Assembly and Mounting 

1.

 

Assemble the breakaway sensor bracket as illustrated in 

Figure 15.

 

 

Figure 15: Nitro Bracket Assembly 

2.

 

Apply a small amount of grease to the rotating surfaces of the bracket. 

 

Figure 16: Nitro Bracket Mounting 

 

FRONT 

Summary of Contents for UC5 MAX

Page 1: ...UC5 MAX Ultrasonic Sensor Upgrade Installation Manual 5468BC MAX ...

Page 2: ...stems International Inc reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously Every effort has been made to ensure the accuracy of the information contained in this manual The technical information in this manual was reviewed at the time of approval for publication ...

Page 3: ...Contents 1 Introduction 1 2 Kit Parts 2 3 MAX Ultrasonic Sensor Installation 3 4 Roll Sensor Removal 6 5 Software Setup 7 6 Appendix A Sensor Bracket Installation 8 7 Appendix B Cable Drawings 12 ...

Page 4: ...garding the parts list or the installation procedure please don t hesitate to contact us Do not use high speed power tools drills when installing hardware The use of dielectric grease is not recommended on any NORAC electrical connections To ensure all stainless steel hardware does not gall or seize apply a light coating of the supplied Permatex Anti seize grease to all threaded parts upon install...

Page 5: ... the severe terrain option has already been installed Follow the installation instructions in Section 3 1 If the sprayer only has one set of brackets near the end of the booms a bracket kit is needed to complete the installation Depending on the type of brackets needed the following kits are available from NORAC Follow the installation instructions in Section 3 2 Part Number Name Quantity 5464BC L...

Page 6: ...nsors as spares 2 Install the sensors E07 into the brackets with the lower serial number on the left Figure 4 and Figure 5 Connect the sensors where the original sensors were disconnected Figure 4 Sensor Serial Number Arrangement Rear Mount Boom The E07 sensors will be mounted in the positions shown in black Figure 5 Sensor Serial Number Arrangement Front Mount Boom ...

Page 7: ...ollow the appropriate set of instructions 3 2 1 Installation with 2 Way Coupler with Terminator 1 Remove the 2 way coupler with terminator E20 from the outer sensor and install it at the inner sensor 2 Install the 3 way coupler E10 at the outer sensor Plug the existing CANbus cable C05 and the sensor cable into the 3 way coupler 3 Connect the CANbus cable C06 between the 2 way coupler with termina...

Page 8: ...at the inner sensor Plug the terminator plug E20 and the sensor cable into the 3 way coupler 3 Connect the CANbus cable C06 between the 3 way couplers Components shown in black are included in this kit Components shown in green are included in the bracket and hardware kit Components shown in blue are existing components Figure 7 Electrical Installation 3 Way Coupler and Terminator Plug ...

Page 9: ... Some machines will have a third roll sensor mounted on the chassis 2 Disconnect and remove all roll sensors Refer to the installation manual for the specific make model of sprayer for roll sensor mounting locations Installation manuals are available at www norac ca 3 Insert the 6 pin plugs P03 into the 8 way coupler where the roll sensors were connected Figure 8 NORAC Roll Sensor Figure 9 NORAC 8...

Page 10: ...t the cabling and hoses are agreeable to the entire range of motion 2 If any functions do not work review the hydraulic and electrical portions of this manual to check for proper installation 3 Turn on the power for the display terminal using the switch on the side 4 The procedure for the installation of the Spray Height Control system is now complete Begin the AUTOMATIC SYSTEM SETUP procedure as ...

Page 11: ...erating heights 4 The bottom of the sensor must be at least 9 inches above the spray nozzles C 5 The bottom of the sensor must be at least 9 inches in front of the spray nozzles and boom structure D Figure 10 Sensor Mounting Guidelines Left Low Profile Right Break Away and Nitro A problem can arise if a sensor is not mounted correctly It is possible for the sensor to read off of the boom instead o...

Page 12: ...he sensor tube depending on the style of bracket Ensure the cable is clear of moving parts and will not be damaged during folding 6 3 Low Profile Bracket Mounting 1 Minimize the distance between the bolts to prevent bending the bracket and prevent the bracket from loosening over time 2 Ensure the bracket is mounted tight against the bottom of the boom minimizing the distance between the boom struc...

Page 13: ...Bracket Assembly 2 Compress the spring and insert it together with the collar into the base 3 Slide the tube through the assembled part 4 Using the bolt and nut tighten the collar to the tube with the sensor tube centered 5 Apply a small amount of grease to the rotating surfaces of the bracket Figure 14 Breakaway Bracket Mounting FRONT ...

Page 14: ...ly and Mounting 1 Assemble the breakaway sensor bracket as illustrated in Figure 15 Figure 15 Nitro Bracket Assembly 2 Apply a small amount of grease to the rotating surfaces of the bracket Figure 16 Nitro Bracket Mounting FRONT ...

Page 15: ...12 7 Appendix B Cable Drawings 7 1 ITEM C06 43210 10 CABLE UC5 NETWORK 18 AWG 10M ...

Page 16: ...Saskatoon SK S7P 0A6 TOPCON Agriculture Americas W5527 Hwy 106 Fort Atkinson WI 53538 TOPCON Precision Agriculture Europe Avenida de la industria 35 Tres Cantos España Spain Support Phone 888 979 9509 E mail tasupportn topcon com Web www norac ca ...

Reviews: