background image

 

 
 
 

7

3.2

 

ITEM C26:  43240-47 – Cable UC5 Interface Switch Box - 50250 

 

 

 

Summary of Contents for Case AFS Pro 300

Page 1: ...Case AFS Pro 300 600 700 Display Kit 20 30 Series Self Propelled Installation Manual 54VT PRO SP01 ...

Page 2: ...NORAC Systems International Inc reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously Every effort has been made to ensure the accuracy of the information contained in this manual The technical information in this manual was reviewed at the time of approval for publication ...

Page 3: ...AWINGS 6 3 1 ITEM C25 50250 Switchbox 6 3 2 ITEM C26 43240 47 Cable UC5 Interface Switch Box 50250 7 3 3 ITEM C30 43250 14 Cable UC5 Battery 2 Pin DT Tee Fused ECU SIG 8 3 4 ITEM C40 43260 07 Cable CANbus 3 Pin DT J1939 9 3 5 ITEM C41 43220 01 Cable Network 14 AWG 1M 10 3 6 ITEM C42 43260 29 Cable Interface DT 4 Pin 12 IN Stub 11 APPENDIX A ALTERNATE CONFIGURATION 12 ...

Page 4: ...t ensure that you have the latest VT software installed The VT software must be Version 25 or newer 1 2 List of Parts Item Part Number Name Quantity C25 50250 SWITCHBOX 1 C26 43240 47 CABLE UC5 INTERFACE SWITCH BOX 50250 1 C30 43250 14 CABLE UC5 BATTERY 2 PIN DT TEE FUSED ECU SIG 1 C40 43260 07 CABLE INTERFACE CAN BUS 3 PIN DT J1939 1 C41 43220 01 CABLE NETWORK 14 AWG 1M 1 C42 43260 29 CABLE INTER...

Page 5: ...Application CANbus is a 4 pin Deutsch connector use cable C42 43260 29 4 Connect the Deutsch plug on cable C40 or C42 to the end of the control module with only one Deutsch connector 5 Connect the power cable C30 to one of the two CANbus connectors on the control module 6 There will be either a 2 pin DT plug or a 2 pin DT receptacle for power Connect the appropriate connector and plug the other wi...

Page 6: ...4 Figure 2 CANbus Interface Installation with Cable C42 ...

Page 7: ...n 4 of the 12 pin plug on C20 Insert the wedge back into the plug Connect C20 to the Thru 2 connector on the input module 3 Connect the 12 pin Deutsch plug on C26 to the OEM 3 connector on the input module Route the other end of the cable to the cab 4 Attach the switch box C25 inside the cab and connect it to cable C26 Some sprayer types may not use all the switch functions Refer to Appendix A for...

Page 8: ...6 3 Cable Drawings 3 1 ITEM C25 50250 Switchbox ...

Page 9: ...7 3 2 ITEM C26 43240 47 Cable UC5 Interface Switch Box 50250 ...

Page 10: ...8 3 3 ITEM C30 43250 14 Cable UC5 Battery 2 Pin DT Tee Fused ECU SIG ...

Page 11: ...9 3 4 ITEM C40 43260 07 Cable CANbus 3 Pin DT J1939 ...

Page 12: ...10 3 5 ITEM C41 43220 01 Cable Network 14 AWG 1M ...

Page 13: ...11 3 6 ITEM C42 43260 29 Cable Interface DT 4 Pin 12 IN Stub ...

Page 14: ...tor Pin Location Connector Pin Location Power White Grey End C26 1 Grey End C26 1 Ground Black Grey End C26 12 Grey End C26 12 Remote Auto Brown Grey End C26 11 Grey End C26 11 Remote Manual Blue Grey End C26 10 Grey Side C20 4 Main Up Purple Grey End C26 9 Grey End C26 9 Main Down Yellow Grey End C26 8 Grey End C26 8 Roll CW Red Grey Side C20 3 Grey End C26 6 Roll CCW Orange Grey Side C20 4 Grey ...

Page 15: ...Saskatoon SK S7P 0A6 TOPCON Agriculture Americas W5527 Hwy 106 Fort Atkinson WI 53538 TOPCON Precision Agriculture Europe Avenida de la industria 35 Tres Cantos España Spain Support Phone 888 979 9509 E mail tasupportn topcon com Web www norac ca ...

Reviews: