READ PRIOR TO ATTEMPTING INSTALLATION
ALWAYS TURN OFF MAIN POWER BEFORE INSTALLATION
INSTALLATION SHOULD BE CARRIED OUT BY YOUR LOCAL ELECTRICIAN
6505 Gayhart Street, Commerce, CA 90040
Tel 323.767.2600 | www.noralighting.com | e-mail: [email protected]
© 2019 Nora Lighting, Inc. All rights reserved. Instructions subject to change without notice.
042419P2
IS-NHIOICDR01
Installation Instructions
NHIOICD
Iolite New Construction Housing
White - neutral
Black - live
green - ground
120v ConneCtIon:
COMMON
WHITE
CONNECTOR 1
WHITE
WHITE/BLK
BLACK
LED EMERGENCY
DRIVER
FLEX A
FLEX B
AC LED
DRIVER
YEL/BLK
OUTPUT (BLK) (-)
CONNECTOR 2
BLUE
OUTPUT (RED) (+)
LED EMERGENCY
DRIVER
FLEX B
AC LED
DRIVER
FLEX A
CONNECTOR 3
LED (BLK) (-)
YEL/BLK
LED EMERGENCY
DRIVER
FLEX A
FLEX B
CONNECTOR 3
LED (RED) (+)
LED (BLK) (-)
LED LOAD
YELLOW
OUTPUT (BLK) (-)
CONNECTOR 2
PhIlIPs BodIne Bsl17C-C2 eM eleCtrICal ConneCtIon For Model nhIoICd-4W and nhIoICd-6W:
ConneCtor 1
ConneCtor 2
ConneCtor 3
COMMON
WHITE
CONNECTOR 1
WHITE
PURPLE (0-10V DIMMING)
FOR LE4 VERSION
GREY (0-10V DIMMING)
WHITE/BLK
BLACK
LED EMERGENCY
DRIVER
FLEX A
FLEX B
AC LED
DRIVER
WALL
SWITCH
UNSWITCHED HOT
WHITE/RED
BLACK
VIOLET (+)
VIOLET
BROWN
BROWN (-)
RED
WHITE
FLEX A
FLEX B
YELLOW
YEL/BLK
CONNECTOR 2
CONNECTOR 3
BLUE
OUTPUT (RED) (+)
LED (RED) (+)
LED (BLK) (-)
LED LOAD
OUTPUT (BLK) (-)