5
NookBox
Installation Guide
SVGS-1 Shock, Vibration & Glass Break Sensor
Supervision
The Sensor will transmit a supervision signal to report its condition regularly according to the user’s setting. The factory default interval is
30-40 minutes. The user can also press the Function Button once to transmit a supervision signal manually.
Sensitivity
The Sensor can send alarm signal to the Control Panel according to different sensitivity levels setting. The sensitivity levels include high,
medium, and low (default). The higher the sensitivity; the easier the sensor is triggered by shock/vibration.
To adjust the sensitivity setting:
1 Remove the battery.
2 Reinsert the battery, the LED indicator will light up briefly for about 1 second.
3 Press and hold the Learn/Test button when the LED indicator is lit up.
4 The LED will begin to flash 3 times:
I.
Release the button when the LED flash for the first time to set sensitivity to Low.
II. Release the button when the LED flash for the second time to set sensitivity to Medium.
III. Release the button when the LED flash for the third time to set sensitivity to High.
•
The detection range of different sensitivity varies depending on the mounting surface materials.
Material
Plated/Tempered/Laminated/Wired Glass
Plywood
Thickness
Minimum 5mm
Maximum 9mm
Sensitivity
Low (Default)
1000mm
N/A
Medium
2500mm
N/A
High
4000mm
1000mm