NookBox KP-35 Installation Manual Download Page 5

5

NookBox

Installation Guide

Remote Keypad KP-35

Removing Device from ZigBee Network

To remove the Keypad from current ZigBee network, the Keypad must be put to Factory Reset to complete device removal. Factory Reset 
function will clear the Keypad of its stored setting information and prompt the Keypad to search for new ZigBee network.

Before removing device, make sure the Keypad is within current ZigBee network signal range.

 

1. 

Delete the Keypad from current control panel / CIE.

 

2.  Press and hold the OK key for 10 seconds, then release the button to reset Keypad.

 

3.  Upon reset, the Keypad will clear current ZigBee network setting and transmit signal to ZigBee coordinator to remove itself from    

 

 

current ZigBee network. It will then actively search for available ZigBee network again and join the network automatically. 

Using Remote Keypad with ZigBee Router

IMPORTANT NOTE

If the Remote keypad installation location is away from your system control panel and requires ZigBee routers to improve signal strength. DO 
NOT use a ZigBee Router without backup battery. A ZigBee router without battery will be powered down during AC power failure and the 
Remote keypad connected to the router will lose connection with ZigBee network. You should plan your Remote keypad installation location 
using only ZigBee router with backup battery.

Operation

When the Keypad is under power saving mode, apply your hand to the Keypad to wake up the device. The LCD display will display the status 
of the system then prompt you to “Enter PIN Code”
You must enter a Control Panel User PIN Code to proceed.
User PIN Code: Enter the User PIN Code programmed in the system control panel and press OK to confirm.

User Menu  

 

•  The Keypad will communicate with the system to retrieve information before entering User Menu. 

 

•  The system is always automatically disarmed upon entering Keypad User Menu.

 

•  The Keypad will exit User Menu automatically after 30 seconds of inactivity.

Away Arm:  

 

 

Select “Arm” and press OK key to confirm. If the ZigBee network coordinator or system control panel is successfully armed, the Re 

 

 

mote Keypad will emit a long beep and the LCD will display “Away Armed”.

 

Home Arm:  

 

 

Select “Home” and press OK key to confirm. If the ZigBee network coordinator or system control panel is successfully armed, the  

 

 

Remote Keypad will emit 3 beeps and the LCD will display “Home Armed”.

 

Alarm Memory:  

 

This option will become available after an alarm has been triggered. Entering the Keypad’s User Menu will be directed to the Alarm  

 

 

Memory option automatically. Press OK to confirm and use  and  key to view the alarm memory. 

 

Fault:  

 

 

This option will only become available if fault event exists in system. To view fault events, select “Fault Display” and press OK key to  

 

 

confirm. Use the  and  keys to view the fault events and press  key to return to menu.

 

If you try to arm the system when fault event exists, the arming will be prohibited and the LCD screen will jump to Fault Display.  

 

Please go to your ZigBee coordinator or system control panel to check and remove the fault condition(s). If you want to force arm the  

 

 

system, select Arm or Home Arm and press OK again. The system will ignore the fault event and enter your selected arm mode.

Log:  

 

Select “Log” and press OK key to view system log. Use the  and  keys to view the events and press  key to return to User Menu

Setting: 

 

 

Select “Setting” and press OK key to enter setting menu. Use the  and  keys to select setting options and press  key to return to User    

 Menu.

Summary of Contents for KP-35

Page 1: ...1 NookBox Installation Guide Remote Keypad KP 35 Remote Keypad KP 35 Installation Guide...

Page 2: ...outs It also has a tamper protection switch which will be activated upon any attempt of unauthorized opening of the cover The Keypad utilizes ZigBee technology for wireless signal transmission ZigBee...

Page 3: ...umeric Keys 5 Key 6 Key 7 Backlit OK Key To confirm the keyed in data or confirm the selection 8 Backlit Key Use this key for deleting a digit canceling the selection aborting the current screen and r...

Page 4: ...e Device Guideline ZigBee is a wireless communication protocol that is reliable has low power consumption and has high transmission efficiency Based on the IEEE802 15 4 standard ZigBee allows a large...

Page 5: ...in the system control panel and press OK to confirm User Menu The Keypad will communicate with the system to retrieve information before entering User Menu The system is always automatically disarmed...

Page 6: ...nsuccessful operation Fault Display will be displayed on the LCD screen along with 3 beeps indicating arming fault Incorrect PIN Code will be displayed on the LCD screen along with 4 beeps indicating...

Page 7: ...t Keypad to default value Reset Default will be displayed on the LCD screen along with 3 beeps indicating successful operation All learnt in data will be cleared Entry Exit Beeps will be disabled Alar...

Page 8: ...8 NookBox Installation Guide Remote Keypad KP 35...

Page 9: ...9 NookBox Installation Guide Remote Keypad KP 35 For more information visit www getnookbox com...

Reviews: