5
NookBox
Installation Guide
Remote Keypad KP-35
Removing Device from ZigBee Network
To remove the Keypad from current ZigBee network, the Keypad must be put to Factory Reset to complete device removal. Factory Reset
function will clear the Keypad of its stored setting information and prompt the Keypad to search for new ZigBee network.
Before removing device, make sure the Keypad is within current ZigBee network signal range.
1.
Delete the Keypad from current control panel / CIE.
2. Press and hold the OK key for 10 seconds, then release the button to reset Keypad.
3. Upon reset, the Keypad will clear current ZigBee network setting and transmit signal to ZigBee coordinator to remove itself from
current ZigBee network. It will then actively search for available ZigBee network again and join the network automatically.
Using Remote Keypad with ZigBee Router
IMPORTANT NOTE
If the Remote keypad installation location is away from your system control panel and requires ZigBee routers to improve signal strength. DO
NOT use a ZigBee Router without backup battery. A ZigBee router without battery will be powered down during AC power failure and the
Remote keypad connected to the router will lose connection with ZigBee network. You should plan your Remote keypad installation location
using only ZigBee router with backup battery.
Operation
When the Keypad is under power saving mode, apply your hand to the Keypad to wake up the device. The LCD display will display the status
of the system then prompt you to “Enter PIN Code”
You must enter a Control Panel User PIN Code to proceed.
User PIN Code: Enter the User PIN Code programmed in the system control panel and press OK to confirm.
User Menu
• The Keypad will communicate with the system to retrieve information before entering User Menu.
• The system is always automatically disarmed upon entering Keypad User Menu.
• The Keypad will exit User Menu automatically after 30 seconds of inactivity.
Away Arm:
Select “Arm” and press OK key to confirm. If the ZigBee network coordinator or system control panel is successfully armed, the Re
mote Keypad will emit a long beep and the LCD will display “Away Armed”.
Home Arm:
Select “Home” and press OK key to confirm. If the ZigBee network coordinator or system control panel is successfully armed, the
Remote Keypad will emit 3 beeps and the LCD will display “Home Armed”.
Alarm Memory:
This option will become available after an alarm has been triggered. Entering the Keypad’s User Menu will be directed to the Alarm
Memory option automatically. Press OK to confirm and use and key to view the alarm memory.
Fault:
This option will only become available if fault event exists in system. To view fault events, select “Fault Display” and press OK key to
confirm. Use the and keys to view the fault events and press key to return to menu.
If you try to arm the system when fault event exists, the arming will be prohibited and the LCD screen will jump to Fault Display.
Please go to your ZigBee coordinator or system control panel to check and remove the fault condition(s). If you want to force arm the
system, select Arm or Home Arm and press OK again. The system will ignore the fault event and enter your selected arm mode.
Log:
Select “Log” and press OK key to view system log. Use the and keys to view the events and press key to return to User Menu
Setting:
Select “Setting” and press OK key to enter setting menu. Use the and keys to select setting options and press key to return to User
Menu.