![Nomix Frontline Classic Instructions Manual Download Page 15](http://html.mh-extra.com/html/nomix/frontline-classic/frontline-classic_instructions-manual_1700017015.webp)
•
Ensure there is no disc attached.
If a disc is present, remove it
using the disc ejector tool.
•
Turn the spray width control to
the ‘OFF’ position.
•
Turn the pacer control to the
calibrate position.
•
Set the flow rate indicator to
‘Prime’.
•
Push the calibration cup on to
the spray head.
•
Select the calibration setting on
the pacer control.
•
Press the trigger ‘on’.
•
Wait up to 20 seconds for
herbicide to appear in the flow
rate window.
•
Press the trigger ‘off’.
•
Press the trigger ‘on’ and
invert the lance to empty the
calibration cup.
•
Press the trigger ‘off’ when the
calibration cup is empty.
Selecting a disc
Select a disc using the following
table. Before connecting the disc, you
must carry out the full calibration
procedure on pages 16 & 17.
15
Disc
Spray Width
Recommended areas of use
Spiral
15cm – 30cm
(6” – 12”)
Spot treatment, narrow
trim and edge work
Square
30cm – 75cm
(12” – 30”)
Trim and edge work, spot
treatment and fence lines
Serrated
75cm – 100cm
(30” – 40”)
Broadcast spraying