SUGGESTED INSTALLATION
NTG25
NOMAD TRANS-FLO™
The suction pipe size should be at least 25mm
(1") diameter or larger if highly viscous
material is being pumped. The suction hose
must be non-collapsible, reinforced type as
the NTG25 is capable of pulling a high vacuum.
Discharge piping should be at least 19mm
(3/4"); larger diameter can be used to reduce
friction losses. It is critical that all fittings and
connections are airtight or a reduction or loss of pump
suction capability will result.
Every pump location should have an air line large
enough to supply the volume of air necessary to
achieve the desired pumping rate.
Unnecessary elbows, bends and fittings should be
avoided. Pipe sizes should be selected so as to keep
friction losses within practical limits. All piping should
be supported independently of the pump.
Expansion joints can be installed to aid in absorbing
the forces created by the natural reciprocating action
of the pump. Flexible connections between the pump
and rigid piping will also assist in minimizing pump
vibration. A surge suppressor should be installed to
protect the pump, piping and gauges from surges and
water hammer.
When pumps are installed in applications involving
flooded suction or suction head pressures, a gate
valve should be installed in the suction line to permit
closing of the line for pump service.
The NTG25 can be used in submersible applications
only when both wetted and non-wetted portions are
compatible with the material being pumped. If the
pump is to be used in a submersible application, a
hose should be attached to the pump’s air exhaust
and the exhaust air piped above the liquid level.
5
PERFORMANCE
NTG25 METAL
PTFE-FITTED
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters
will fall in the center of the pump performance curve.
Height ............................................. 279 mm (11.0")
Width .............................................. 267 mm (10.5")
Depth ............................................... 185 mm (7.3")
Est. Ship Weight .................Aluminum 12 kg (26 lbs)
Air Inlet .................................................6 mm (1/4")
Inlet ....................................................... 25 mm (1")
Outlet .................................................19 mm (3/4")
Suction Lift ...................................... 1.83 m Dry (6')
9.45 m Wet (31')
Displacement/Stroke ................. 0.19 l (0.050 gal.)
1
Max. Flow Rate .............................. 95 Ipm (25 gpm)
Max. Size Solids .................................3.2 mm (1/8")
1
Displacement per stroke was calculated at 4.8 bar
(70 psig) air inlet pressure against a 2 bar (30 psig)
head pressure.
Example:
To pump 45.4 lpm (12.0 gpm) against
a discharge pressure head of 2.7 bar (40 psig)
requires 4.1 bar (60 psig) and 21.1 Nm
3
/h (13 scfm)
air consumption. (See dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air
supply pressure.
Summary of Contents for NTG25 TRANS-FLO
Page 11: ...10 EXPLODED VIEW RUBBER DIAPHRAGMS NTG25 NOMAD TRANS FLO EXPLODED VIEW PTFE DIAPHRAGMS...
Page 13: ...NTG25 RUBBER FITTED NTG25 NOMAD TRANS FLO 12...
Page 15: ...NTG25 NOMAD TRANS FLO NTG25 PTFE FITTED 14...
Page 16: ...1351 Park Ave Suite 104 Redlands CA USA 92373 909 798 9532 A JDA Global Company...