The suction pipe size should be at least 25mm  

(1") diameter or larger if highly viscous 

 

material is being pumped. The suction hose 

must be non-collapsible, reinforced type as 

the NTG25 is capable of pulling a high vacuum.  

Discharge piping should be at least 19mm 

 

(3/4"); larger diameter can be used to reduce 

 

friction losses. It is critical that all fittings and 

connections are airtight or a reduction or loss of pump  

suction capability will result. 

Every pump location should have an air line large 

enough to supply the volume of air necessary to 

achieve the desired pumping rate.

Unnecessary elbows, bends and fittings should be

avoided. Pipe sizes should be selected so as to keep 

friction losses within practical limits. All piping should 

be supported independently of the pump.

Expansion joints can be installed to aid in absorbing 

the forces created by the natural reciprocating action 

of the pump. Flexible connections between the pump 

and rigid piping will also assist in minimizing pump 

vibration. A surge suppressor should be installed to 

protect the pump, piping and gauges from surges and 

water hammer. 

When pumps are installed in applications involving 

flooded suction or suction head pressures, a gate

valve should be installed in the suction line to permit 

closing of the line for pump service. 

The NTG25 can be used in submersible applications 

only when both wetted and non-wetted portions are 

compatible with the material being pumped. If the 

pump is to be used in a submersible application, a 

hose should be attached to the pump’s air exhaust 

and the exhaust air piped above the liquid level. 

5

PERFORMANCE

NTG25 METAL  

PTFE-FITTED

Flow rates indicated on chart were determined by pumping water.

For optimum life and performance, pumps should be specified so that daily operation parameters 
will fall in the center of the pump performance curve.

Height ............................................. 279 mm (11.0")
Width .............................................. 267 mm (10.5")
Depth ............................................... 185 mm (7.3")
Est. Ship Weight .................Aluminum 12 kg (26 lbs)
Air Inlet .................................................6 mm (1/4")
Inlet ....................................................... 25 mm (1")
Outlet .................................................19 mm (3/4")
Suction Lift ...................................... 1.83 m Dry (6')
 

9.45 m Wet (31')

Displacement/Stroke ................. 0.19 l (0.050 gal.) 

1

Max. Flow Rate .............................. 95 Ipm (25 gpm)
Max. Size Solids .................................3.2 mm (1/8")

1

Displacement per stroke was calculated at 4.8 bar 

(70 psig) air inlet pressure against a 2 bar (30 psig) 
head pressure.

Example:

 To pump 45.4 lpm (12.0 gpm) against  

a discharge pressure head of 2.7 bar (40 psig)  
requires 4.1 bar (60 psig) and 21.1 Nm

3

/h (13 scfm) 

air consumption. (See dot on chart.)

Caution: Do not exceed 8.6 bar (125 psig) air 

supply pressure.

Summary of Contents for NTG25 TRANS-FLO

Page 1: ...O P E R A T I O N M A N U A L AIR OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S S Models A JDA Global Company 1 14 rev 3 NTG25 NOMAD TRANS FLO...

Page 2: ...e for all applications The information provided is the best thinking available regarding chemical compatibility The guide however does not provide a recommendation 2 Always wear safety glasses during...

Page 3: ...RENE Green Dot SN SANTOPRENE TF PTFE VALVE BALL BN BUNA N Red Dot FS HYTREL ND EPDM Blue Dot NE NEOPRENE Green Dot TF PTFE White SN SANTOPRENE VALVE SEAT A ALUMINUM S STAINLESS Valve seat o ring requi...

Page 4: ...es the limit of its discharge stroke the air valve redirects pressurized air to the back side of the diaphragm B The pressurized air forces diaphragm B away from the center block while pulling diaphra...

Page 5: ...2 bar 30 psig head pressure Example To pump 68 1 lpm 18 0 gpm against a discharge pressure head of 2 7 bar 40 psig requires 4 1 bar 60 psig and 18 7 Nm3 h 11 scfm air consumption See dot on chart Caut...

Page 6: ...are installed in applications involving flooded suction or suction head pressures a gate valve should be installed in the suction line to permit closing of the line for pump service The NTG25 can be...

Page 7: ...h pump and out air exhaust 5 Check type of lubricant being used ISO 15 5 wt recommended Pump runs but little or no product flows 1 Check for pump cavitation slow pump speed down to match thickness of...

Page 8: ...carriage bolts that secure the top and bottom manifolds to the center section Step 1 Before starting disassembly mark a line from each liquid chamber to its corresponding air chamber This line will a...

Page 9: ...mical attack or abrasive wear Step 6 With the 3 4 box wrench or by rotating the diaphragm by hand remove the diaphragm assembly Step 7 Due to varying torque values one of the following two situations...

Page 10: ...the shifting function of the pump it is necessary that they be located in the proper grooves When bushing wear becomes excessive a new center block must be used CENTER BLOCK SEAL DISASSEMBLY Step 8 T...

Page 11: ...10 EXPLODED VIEW RUBBER DIAPHRAGMS NTG25 NOMAD TRANS FLO EXPLODED VIEW PTFE DIAPHRAGMS...

Page 12: ...O ring 2 N02 3201 52 6 Air Valve Gasket 1 N02 2600 52 7 Center Section 1 N02 3151 20 225 8 Muffler Plate 1 N02 3180 20 9 Muffler Plate Gasket 1 N02 3500 52 500 10 Air Valve Cap Screw 1 4 20 x 6 1 4 4...

Page 13: ...NTG25 RUBBER FITTED NTG25 NOMAD TRANS FLO 12...

Page 14: ...on 2 N02 3750 01 15 Outer Piston 2 N02 4601 01 16 Shaft Stud 2 N02 6150 08 17 Liquid Chamber 2 N02 5000 01 18 Discharge Manifold 1 N02 5020 01 19 Inlet Manifold 1 N02 5080 01 20 Manifold Bolt 3 8 16 x...

Page 15: ...NTG25 NOMAD TRANS FLO NTG25 PTFE FITTED 14...

Page 16: ...1351 Park Ave Suite 104 Redlands CA USA 92373 909 798 9532 A JDA Global Company...

Reviews: