background image

NoLand Engineering, Inc. 

N183-41 Serial Multiplexer Installation & Operation Manual 

Page 1 of 6 

www.navstore.com

www.navstore.com

www.navstore.com

www.navstore.com    

Great Lakes Marine Specialties

Great Lakes Marine Specialties

Great Lakes Marine Specialties

Great Lakes Marine Specialties    

800

800

800

800----821

821

821

821----0207 USA & Canada

0207 USA & Canada

0207 USA & Canada

0207 USA & Canada    

952

952

952

952----925

925

925

925----1285 All other Countries

1285 All other Countries

1285 All other Countries

1285 All other Countries    

 
General Description

 

Each N183-41 Serial Multiplexer provides four NMEA-0183 opto-isolated listener ports 
and one talker port. Multiple units may be interconnected to provide additional listener 
ports (i.e., two units will provide seven listener ports and three units will provide ten lis-
tener ports). 
 
The talker port enables the computer to send "query" messages to instruments 
equipped with a "listen" port, such as a LORAN or GPS receiver. The Talker port util-
izes a standard RS-422 differential driver as specified by the Standard. 
 
A standard RS-232 interface is provided for connection to the host computer. The de-
fault baud rate is 4800 so that is also NMEA-0183 compatible. The N183-41 is fully 
compliant with the National Marine Electronics Association NMEA-0183 Standard for 
Interfacing Marine Electronic Devices, Version 2.00, 1992.  
 

Installation

 

Installation of the N183-41 requires connection to a power source (8-16VDC), the in-
struments, and the computer. All connections are made via a 16-pin terminal strip as 
detailed below: (See Fig. 1) 

Reviews: