Replace the old ONT with a new ONT on a flat surface, such as a desk or shelf.
7
Connect the Ethernet cables directly to the RJ-45 ports; see
Figure 7-1, “XS-2426G-B indoor
for the location of the RJ-45 ports.
8
Connect the POTS cable directly to the RJ-11 port as per local practices; see
2426G-B indoor ONT connections” (p. 75)
for the location of the RJ-11 ports.
9
DANGER
Hazard
Fiber optic cables transmit invisible laser light. To avoid eye damage or blindness, never look
directly into fibers, connectors, or adapters.
If required, have approved service personnel who are trained to work with optic fiber clean the
fiber optic connection. See the
Nokia ONT Configuration, Management, and
Troubleshooting Guide
for more information about fiber optic handling, inspection, and
cleaning.
10
DANGER
Hazard
Fiber cables transmit invisible laser light. To avoid eye damage or blindness, never look directly
into fibers, connectors, or adapters.
WARNING
Equipment Damage
Be careful to maintain a bend radius of no less than 1.5 in. (3.8 cm) when connecting the fiber
optic cable. Too small of a bend radius in the cable can result in damage to the optic fiber.
Connect the fiber optic cable with SC/APC adapter into the SC/APC connector on the bottom of
the ONT.
Note:
Fiber cable preparation varies depending on the type and size of the inside or
outside plant fiber cable being spliced to the SC/APC fiber optic pigtail cable.
Replace a XS-2426G-B indoor ONT