RM-4/RM-5
CCS Technical Documentation
Troubleshooting Instructions
28
COMPANY CONFIDENTIAL
ISSUE 1 02/2004
Copyright © 2003 Nokia. All Rights Reserved.
By measuring with an oscilloscope at RXIP or RXQP on a working GSM 900 receiver this pic-
ture should be seen.
Signal amplitude peak-peak 789 mV
DC offset 1.2 V
Figure 8: RX900 I/Q signal waveform