RH-21
Troubleshooting
CCS Technical Documentation
Page 12
Nokia Corporation Confidential
Issue 1 05/2003
Charging
Note: The charging voltage and current can be checked by connecting the phone to the service soft-
ware and reading the ad- converter values of the vchar and ichar.
If charging fails when the ACP-9 or the LCH-9 is used, but works with ACP-7, ACP-8, and
LCH-8, check that the charge control pin of the system connector is connected to the
ground.
Cx82
"The Prommer has detected a wrong ID byte in the mes-
sage, which it has received from the Phone."
FbusTx from UPP->UEM->Prommer
A204
Cx83
Cx84
Cx85
"The flash manufacturer and device IDs in the existing
Algorithm files do not match with the IDs received from
the target phone."
"The Prommer has not received Phone acknowledge to
the message."
"The Phone has generated NAK signal during data block
transfer."
"Data block handling timeout"
Flash
UPP
VIO/VANA?
Signals between UPP-Flash
Mbus from Prommer->UEM-
>UPP(MbusRx)
FbusRx from Prommer->UEM->UPP
FbusTx from UPP->UEM->Prommer
Cx87
"Wrong MCU ID."
RFClock
UPP(Vcore)
Startup
for
flashing
Required startup for flashing
Vflash1
VBatt