6. To choose a product in Phoenix:
From the File menu, choose “Choose Product” and select RA-8 from the list
or
from the File menu, choose “Scan Product”.
7. From the toolbar, set operating mode to "Local"
.
8. From the Testing menu, choose “RF Controls”.
9. In the “RF Controls” window:
- Select band "GSM900" or "GSM 1800" or "GSM1900" (Default = "GSM900").
- Set Active unit to "Tx" (Default = "Rx").
- Set Operation mode to "Burst" (Default = "Burst").
- Set Tx data type to "Random" (Default = "All1").
- Set Rx/Tx channel to 37 on GSM900 band or 700 on GSM1800 band or 661 on
GSM1900 (Defaults).
- Set Tx PA mode to "Free" (Default).
- Set power level to 5 (Default = 19) on GSM900 or to 0 (Default = 15) on GSM1800
or GSM1900.