Soldering Jig MJS-75

The Soldering Jig MJS-75 is used for soldering (in automatic soldering
machines) and as a rework jig for system module, if special fixtures (like
extra feet) are used.

Product Code

Module Jig MJS-75:

0770233

View of MJS-75

Summary of Contents for NSM-5 SERIES

Page 1: ...PAMS Technical Documentation NSM 5 Series Transceivers Issue 1 02 2002 Nokia Corporation Service Tools ...

Page 2: ...oduct Code 8 View of MJS 75 8 Flash Battery BBF 1 9 Product Code 9 View of BBF 1 9 Flash Loading Adapter FLA 10 10 Sales package code 10 View of FLA 10 10 View of FLC 2 10 Battery Connector Extractor Tool SRT 3 11 Product Code 11 View of SRT 3 11 Flash Loading Adapter FLA 7 Sales Pack 12 Sales package code 12 View of FLA 7 12 Flash Prommer FPS 4S Sales Pack 13 Sales package code 13 View of FPS 4 1...

Page 3: ...C 1B 20 Product Code 20 View of PCC 1B 20 Power Cable PCS 1 21 Product Code 21 View of PCS 1 21 DC Cable SCB 3 22 Product Code 22 View of SCB 3 22 Service Cable XMS 3 23 Product code 23 View of XMS 3 23 RF Cable XRF 1 24 Product code 24 View of XRF 1 24 RF Cable XRS 3 25 Product code 25 View of XRS 3 25 Modular T adapter 26 Product Code 26 View of Modular T adapter 26 Modular Cable Jack Connector ...

Page 4: ...NSM 5 Service Tools PAMS Technical Documentation Page 4 Issue 1 02 2002 Nokia Corporation FLS 4 POS Point Of Sale Flash Device Sales Pack 29 Product Code 29 View of FLS 4 29 ...

Page 5: ...ctional tests to enable connection to test measurument devices to generate accurate 4 1 and 8 4 voltage for Vbatt and Vin Vchar lines to generate accurate 500mA current for charging calibration Vin line to generate 10 ms IBI pulse to BTMP line NOTE JBU 6 cover should be closed during measurements Product Code Service Box JBU 6 0770153 View of JBU 6 RF Adapter RAF 5 for Service Box JBU 6 RF Adapter...

Page 6: ...ols PAMS Technical Documentation Page 6 Issue 1 02 2002 Nokia Corporation Service Box JBU 6 cont Pinset Cable SCD 6 for Service Box JBU 6 Spare part for JBU 6 Sales Package Code Pinset Cable SCD 6 0080329 View of SCD 6 ...

Page 7: ...n picture contains two changeable over voltage protection components SM Fuse F2 0 A 32V 1206 F 001 T 5119002 larger of the two VWM 5 6V VC15 5 R 008 T 1825019 Product Code Module Jig MJS 9 0770154 View of MJS 9 NOTE RJ9 Connector Module information Note The nominal supply voltage for MJS 9 is 8 0 V The supply voltage must not exceed 15 0 V MJS 9 has overvoltage protection ...

Page 8: ...1 02 2002 Nokia Corporation Soldering Jig MJS 75 The Soldering Jig MJS 75 is used for soldering in automatic soldering machines and as a rework jig for system module if special fixtures like extra feet are used Product Code Module Jig MJS 75 0770233 View of MJS 75 ...

Page 9: ... battery during flashing The zoom in picture contains two changeable over voltage protection components SM Fuse F2 0 A 32V 1206 F 001 T 5119002 larger of the two VWM 5 6V VC15 5 R 008 T 1825019 Product Code Flash Battery BBF 1 0775206 View of BBF 1 Note The nominal supply voltage for BBF 1 is 8 0 V The supply voltage must not exceed 15 0 V BBF 1 has overvoltage protection ...

Page 10: ...FLA 10 The Falsh Loading Adapter FLA 10 is used in place of the phone s normal battery during service to supply a controlled operating voltage Sales package code Falsh Loading Adapter FLA 10 0081346 Sales package contains Falsh Loading Adapter FLA 10 bulk 0770229 DC Cable FLC 2 0730185 View of FLA 10 View of FLC 2 ...

Page 11: ...n Page 11 Issue 1 02 2002 Nokia Corporation Battery Connector Extractor Tool SRT 3 The Battery Connector Extractor Tool is used to remove the battery con nector from the frame Product Code Battery Connector Extractor Tool SRT 3 0770226 View of SRT 3 ...

Page 12: ... Power is supplied to FLA 7 from the Flash Security Box TDF 4 via the DC cable PCC 1 The PCC 1 cable can be replaced with a Travel Charger ACH 6 and is connected to the Flash Prommer FPS 4S with the cable AXS 5 The sales pack includes Flash Loading Adapter FLA 7 0770119 Service Cable XCM 5 0730142 Power Cable SCF 7 0730141 Service Cable assy AXS 5 0730091 Sales package code Flash Loading Adapter F...

Page 13: ... to the flash prommer and then loading the new SW from the prommer to the phone When updating more than one phone in succession the MCU software only needs to be loaded to the prommer once The sales pack includes Flash Prommer FPS 4 0750090 Charger ACL 3E 0680015 Printer cable IBM DB25F 57 30360 0730029 D9 D9 Cable AXS 4 0730090 Flash Prommer software 3 disk 0774043 Flash Device Support 3 disk0774...

Page 14: ...e Fill in the enclosed Activation Request Form and fax to NMP Salo to get the activation code Note 2 The infra red module JLP 1 P N 0750079 is not included in the TDF 4 sales package Product Code Security Box TDF 4 0770106 View of TDF 4 View of IR Data Interface Module JLP 1 IR Data Interface Module JLP 1 fits in the Security Box TDF 4 and can be used to perform IR tests with WinTesla Product Code...

Page 15: ...e 15 Issue 1 02 2002 Nokia Corporation Service Cable AXS 4 The D9 D9 Service Cable AXS 4 is used to connect two 9 pin D connectors e g between PC and TDF 4 seurity box Cable lenght is 2 meters Product code D9 D9 Service Cable AXS 4 0730090 View of AXS 4 ...

Page 16: ...16 Issue 1 02 2002 Nokia Corporation Service Cable AXS 4U The D9 D9 Service Cable AXS 4U is used to connect two 9 pin D connectors e g between PC s serial port and FLS 2D Cable length is 30 cm Product code D9 D9 Service Cable AXS 4U 0730163 View of AXS 4U ...

Page 17: ...cal Documentation Page 17 Issue 1 02 2002 Nokia Corporation D15 D15 Cable AXS 5 The D15 D15 Cable AXS 5 is used to connect two 15 pin D connectors e g between FLA 5 7 and FPS 4S Product Code D15 D15 Cable AXS 5 0730091 View of AXS 5 ...

Page 18: ...cumentation Page 18 Issue 1 02 2002 Nokia Corporation MBUS Cable DAU 9S The MBUS Cable DAU 9S has a modular connector and is used with the service Audio Box JBA 4 or a modular T adapter Product Code MBUS Cable DAU 9S 0730108 View of DAU 9S ...

Page 19: ...Service Tools PAMS Technical Documentation Page 19 Issue 1 02 2002 Nokia Corporation DC Cable AXD 1 The DC Cable AXD 1 is used e g to connect FLA 7 and TDF 4 Product Code DC Cable AXD 1 0730144 View of AXD 1 ...

Page 20: ...Technical Documentation Page 20 Issue 1 02 2002 Nokia Corporation DC Charging Cable PCC 1B The DC Cable PCC 1 is used e g to connect FLA 5 and TDF 4 Product Code DC Cable PCC 1B with modular RJ connector 0730053 View of PCC 1B ...

Page 21: ...tion Page 21 Issue 1 02 2002 Nokia Corporation Power Cable PCS 1 The Power Cable PCS 1 is used to connect the module jigs MJS 9 and JBU 6 to an external power supply Can be used with FPS 4 also Product Code Power Cable PCS 1 0730012 View of PCS 1 ...

Page 22: ...22 Issue 1 02 2002 Nokia Corporation DC Cable SCB 3 The DC Cable SCB 3 is used to connect the Service Battery to the charger connection Vin of the phone when doing the charger calibration service procedure Product Code DC Cable SCB 3 0730114 View of SCB 3 ...

Page 23: ...ce Tools PAMS Technical Documentation Page 23 Issue 1 02 2002 Nokia Corporation Service Cable XMS 3 XMS 3 is a modular cable for flashing and service purposes Product code Service Cable XMS 3 0730174 View of XMS 3 ...

Page 24: ...nical Documentation Page 24 Issue 1 02 2002 Nokia Corporation RF Cable XRF 1 RF cable XRF 1 is used to connect RF Test adapter AAT 8 or Test frame MJS 9 to RF measurement equipment Product code RF Cable XRF 1 0730085 View of XRF 1 ...

Page 25: ...ls PAMS Technical Documentation Page 25 Issue 1 02 2002 Nokia Corporation RF Cable XRS 3 RF cable XRS 3 is used to connect JBU 6 Service Box to RF measurement equipment Product code RF Cable XRS 3 0730184 View of XRS 3 ...

Page 26: ...cumentation Page 26 Issue 1 02 2002 Nokia Corporation Modular T adapter The modular T adapter is a suitable branching unit to provide the needed parallel modular connections Product Code Modular T adapter 4626134 View of Modular T adapter ...

Page 27: ...orporation Modular Cable Jack Connector The Modular Cable Jack Connector is a suitable for connecting two Service Flash Batteries BBF 1 together in Warranty Transfer Product Code Modular Cable Jack Connector available eg as AMP code P N 555052 1 View of Modular Cable Jack Connector ...

Page 28: ...lel LPT port of the PC Whithout the dongle present it is not possible to use the service software Printer or any such device can be connected to the PC through the dongle if needed Caution Make sure thet you have switched off the PC and the printer before making connections Caution Do not connected the PKD 1 to the serial port You may damage your PKD 1 Product Code SW Security Device PKD 1 0750018...

Page 29: ...okia Corporation FLS 4 POS Point Of Sale Flash Device Sales Pack FLS 4 is a dongle and flash device incorporated into one package developed specifically for POS use Product Code Sales Pack Europe Africa 0081483 Sales Pack APAC 0081481 Sales Pack Americas 0081482 View of FLS 4 ...

Page 30: ...NSM 5 Service Tools PAMS Technical Documentation Page 30 Issue 1 02 2002 Nokia Corporation This page intentionally left blank ...