&&67HFKQLFDO'RFXPHQWDWLRQ
1+0
,VVXH
&RS\ULJKW
È
1RNLD$OOULJKWVUHVHUYHG
3DJH
6\QWKHVL]HUWURXEOHVKRRWLQJGLDJUDP
)LJXUH
Synthesizer troubleshooting
Set with RF Controls:
-Active Unit = Rx
Operation Mode = Continuous
Check with RF probe
4G VCO out signal
3769.6 MHz (GSM900)
OK?
3685.6 MHz (GSM1800)
Level>–10dBm *
*When 1kOhm passive probe is used,
correct measurement result by +26dB
Synthesizer OK
Yes
VCO out signal level<-10dBm ?
Check balun output levels
and solder joints.
OK ?
Replace
faulty components
No
Yes
Check with oscilloscope
VCO control voltage
from VCO pin
0V ?
Yes
Yes
Check with oscilloscope
>4.0V ?
Yes
Yes
Replace
VCO
No
Check output signal
Yes
on 1GHz span.
Signal found on
incorrect frequency ?
No
and solder joints.
OK ?
Check balun output levels
OK?
Check with oscilloscope
4G VCO Vcc=2.7V
Baseband
troubleshooting
No
Yes
Replace
faulty components
OK ?
Check VCO control loop
components.
No
No
VCO control voltage
from VCO pin
Replace
VCO
Yes
No