8.1.4.1.2.1 Prerequisites
• The OXO Connect must be operational
• A free IP address must be available for the set
• A port with PoE must be available on a switch
8.1.4.1.2.2 Configuring the User in OMC
To create a generic SIP set:
1.
In OMC, go to
Users/Base stations List
.
2.
Select a
No.
,
IP access
and click on the
Add
button.
3.
Select
IP terminal
and enter a
Name
.
4.
Select the newly created user in the list and select
Basic SIP Phone
or
Open SIP Phone
in the
combo box.
See the different features relating to basic or open SIP modes: section
Services offered on SIP
and DECT (IP-DECT) sets
in document [3].
5.
Click the
Modify
button.
6.
Click the
Details
button. The
User
window is opened.
7.
Click the
IP/SIP
button. The
IP/SIP parameters
window is opened.
8.
In the
SIP parameters
tab, click the
SIP password reset
button. A new password is generated in
the
SIP password
field.
9.
A virtual MAC Address is automatically generated but it can be replaced by the real MAC Address
of the SIP device.
Note:
The MAC Address must be unique and is used to identify the subscriber in the OXO Connect call handling (SIP
password is used for authentication).
10.
Note this new password safely. It will be requested during the generic SIP set configuration
(
Configuring the generic SIP set
on page 130).
8.1.4.1.2.3 Connecting the Set
This section describes how to:
• Connect a generic SIP set to the LAN (Local Area Network)
• Connect the power supply
Prerequisites
None
Connecting a SIP set to the LAN
Note:
If the set is supplied via Ethernet, ensure you are using a 802.3af standard-compatible switch.
To connect the set to the LAN:
• Plug the RJ45 cable into the set's LAN connector.
• Connect the RJ45 cable to the LAN.
Connecting Power Supply (Optional)
To supply power via an AC/DC external adapter:
• Plug the appropriate cable from the adapter into the set's power supply connector.
• Connect the plug from the adapter to the mains power supply.
8.1.4.1.2.4 Configuring the generic SIP set
The following parameters must be entered through the MMI or web interface when available:
Chapter
8
Device commissioning
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual
130/216