Configure a G-240W-C indoor ONT
76
7368 ISAM ONT G-240W-C Product Guide
Edition 01
Issue: 01
3
Click Refresh to update the displayed information.
4
STOP. This procedure is complete.
Procedure 12
Optics module status retrieval
1
Select Status > Optics Module Status from the top-level menu in the GPON Home Gateway
window, as shown in Figure
Figure 25
Optics module status window
Table
describes the fields in the Optics module status window.
Table 21
Optics module status parameters
Field
Description
Laser Bias Current (ONT ANI-ONT-Side Optical
Measurements)
Laser bias current, measured in uA
Optics Module Voltage (ONT ANI-ONT-Side Optical
Measurements)
Optics module voltage, measured in V
Optics Module Temperature (ONT ANI-ONT-Side Optical
Measurements)
Optics module temperature, measured in C
Rx Optics Signal Level at 1490 nm (ONT ANI-ONT-Side
Optical Measurements)
Received optics signal level at 1490 nm,
measured in dBm
Tx Optics Signal Level at 1310 nm (ONT ANI-ONT-Side
Optical Measurements)
Transmitted optics signal level at 1310 nm,
measured in dBm
Lower (ONT ANI-ONT-Side Optical Measurements-Optical
Threshold)
Lower optical threshold, measured in dBm
(1 of 2)
R05.05.01 | December 2016 | 3FE 46690 AAAA TCZZA | Edition 01