7368 ISAM ONT G-240W-C Product Guide
Replace a G-240W-C indoor ONT
Issue: 01
Edition 01
63
6.6
Procedure
Use this procedure to replace a G-240W-C indoor ONT.
1
Deactivate the ONT services at the P-OLT.
If you are using the SLID feature, this step is not required. The ONT and the services can
remain in service (IS).
i
Use the RTRV-ONT command to verify the ONT status and th associated services.
Record the serial number or the SLID of the ONT displayed in the command output.
Example:
RTRV-ONT::ONT-1-1-1-1-1;
ii
If the ONT is in service, place the ONT in OOS state.
Example:
ED-ONT::ONT-1-1-1-1-1;
2
If used, disable the Wi-Fi service by pressing the WLAN button; see Figure
of the WLAN button.
Figure 18
G-240W-C indoor ONT connections
3
Power down the unit by using the on/off power switch.
ON/OFF
POWER
USB2
USB1
LAN4
LAN3
LAN2
LAN1
TEL1
TEL2
WLAN
RESET
WPS2.4G
WPS5G
W
a
ll
mo
u
nting
hole
W
a
ll
mo
u
nting
hole
POT
S
port
s
(2)
(RJ-11)
Ethernet
port
s
(4)
(RJ-45)
U
S
B
port
s
(2)
Wi-Fi
s
ec
u
rity
bu
tton
s
2.4G
a
nd 5G
Re
s
et
bu
tton
Power
inp
u
t
Fi
b
er optic
port
Wirele
ss
on/off
bu
tton
On/off
bu
tton
25272
R05.05.01 | December 2016 | 3FE 46690 AAAA TCZZA | Edition 01