![Nokia 1606Arte Service Manual Download Page 45](http://html.mh-extra.com/html/nokia/1606arte/1606arte_service-manual_252250045.webp)
RH-109
BB Troublesh0oting and Manual Tuning Guide
Figure 2 High-level power sequences timing diagram
Table 1 Power-on circuit performance specifications
Parameter
Comments
Min
Typ
Max
Units
t
reg1
Power-on event to first regulator enable
3
0 6
10
ms
t
reg
Delay between regulator turn-ons
4
0.122
ms
t
settle
Regulator settling time
4
0.122
ms
t
reset1
Last regulator on to PON_RESET_N = H
10
20
30
ms
t
pshold
PS_HOLD timeout
133
200
300
ms
t
reset0
PON_RESET_N = L to first regulator off
6.67
10
15
ms
t
off
Delay between regulator turn-offs
5
1.6
2
2.4
ms