MELODIE
CONVECTOR HEATER
OPERATING INSTRUCTIONS
INSTALLATION
POSITION
The appliance should be mounted in a horizontal
position on the wall brackets supplied. It should only be
operated when in the upright position with the control
panel at the top.
Cable entry on the right
FIXING
Remove the wall mounting bracket from the rear of the
unit by depressing the clips at the top of the bracket
with a screwdriver.
Fix wall bracket to wall through the four screw holes
provided. (Three on some smaller output models).
Do NOT locate the heater immediately below a fixed
socket outlet or connection box.
ELECTRICAL CONNECTION
The electrical installation must be carried out by a
competent electrician in accordance with current IEE
regulations for Electrical Equipment in Buildings.
The heater is fitted with a length of flexible cable for
connection to the fixed wiring of the premises through a
suitable connection box incorporating a double pole
isolating switch with a contact separation of at least
3mm, positioned adjacent to the heater.
The black control wire is designed only to carry a
signal from a compatible remote programmer or
switching device.
If the black pilot wire is not being used with a
compatible programming or switching
device it
should be terminated and insulated within the
fused spur box.
IMPORTANT: Ensure that the wires are fitted correctly to
the connecting box terminals.
BROWN: LIVE/PHASE
BLUE : NEUTRAL
BLACK : CONTROL WIRE
WARNING: DO NOT CONNECT THIS
APPLIANCE TO EARTH AS IT IS DOUBLE
INSULATED.
BATHROOM INSTALLATION
These heaters are splash proof to IPX4 standard.
IMPORTANT – if the heater is installed in a room
containing a bath or shower, it must be installed so that a
person using a bath or shower cannot touch switches and
other controls.
OPERATION
MULTI-FUNCTION ELECTRONIC CONTROLS
The electronic controls for this appliance have been
designed to give you maximum economy.
A: FUNCTIONS WHEEL
Off
Heat off
Comfort: Thermostat setting between 1-9
Economy: Temperature reduction mode. Room
temperature is reduced by amount shown on
button (Ref.D)
✻
Frost protection: the convector switches on when
the temperature falls to around 7°C. Gives
maximum econmomy with no risk of freezing
pipes or condensation for long periods of
absence.
Programming: when signalling through the pilot
wire to a remote programmer or switching
device.
B: TEMPERATURE
Use the thermostat dial (B) to select your desired room
temperature. The markings on the dial are in
approximately 3.5°C increments. The maximum setting
(9) is around 35 °C which means the heater will nor mally
remain on continuously. The easiest way to find your
comfort setting is to turn the dial to maximum. When the
temperature in the room has reached your ideal comfort
level, turn the dial back until the thermostat switches off
(the neon light will go out). Leave at this setting and the
heater will operate as necessary to maintain this room
temperature.
C: THERMOSTAT LIGHT
Light on = Element heating
Light off = Element reached required heating level
D: ECONOMY level adjustment button: for setting the
amount by which the temperature is to be reduced
(for