14
2.2 SFP ports connection
The SFP port of th
NX-5610-24G4F
only supports 10
Gigabit fiber modules. Pls use standard SFP module products.
The process of installing a fiber module on a switch is as follows:
1. Grasp the fiber module from the side and insert it smoothly along the SFP port slot of
the switch until the fiber module is in close contact with the switch
2. Confirm the Rx and Tx ports of the fiber module when connecting, insert one end of the
fiber into the Rx and Tx ports, ensure that the Tx and Rx ends of the interface are
correctly connected, and the other end of the fiber is connected to another device;
3. After power-on, check the status of the corresponding indicator. If the indicator is on,
the link is up. If the indicator is off, the link is down. Check the line and confirm that the
peer device is enabled.
•
It is not allowed to excessively bend the fiber, and its radius of curvature should be no less
than 10cm;
•
Ensure the cleanliness of the fiber end face;
•
Please do not look directly into the fiber optic connector with your eyes, as this may cause
eye damage.
2.3 Check before power-on
Check that the power supply of the power outlet meets the switch
specifications.
Check that the power supply, switch, and rack are properly grounded.
Check whether the switch is connected to other network devices.
2.4 device initialization
The switch will automatically initialize after the power is turned on and the power switch is
turned on.
The indicator light will appear as follows:
Note: