Contacting NOCO

.

About G1100.

 The NOCO Genius

®

 G1100 represents 

some of the most innovative and advanced technology on 

the market, making each charge simple and easy. It is quite 

possibly the safest and most efficient charger you will ever 

use. The G1100 is designed for charging all types of 6V & 

12V lead-acid and 12V lithium-ion batteries, including Wet 

(Flooded), Gel, MF (Maintenance-Free), CA (Calcium), EFB 

(Enhanced Flooded Battery), AGM (Absorption Glass Mat), 

and LIB (Lithium Ion) batteries. It is suitable for charging 

battery capacities from 2 to 40 Amp-Hours and maintaining 

all battery sizes.

Mounting.

 The G1100 has two (2) external holes for 

mounting. Mount the charger in a desired location with 

#6 self-drill screws.  Make sure there are no obstructions 

behind the mounting surface. It is important to keep in 

mind the distance to the battery. The DC cable length from 

the charger, with either the battery clamp or eyelet terminal 

connectors, is approximately 75-inches (1,900mm). Allow 

for 12-inches (304mm) of slack between connections. 

Charging Modes.

 The G1100 has five (5) modes: 

Standby, 12V NORM, 12V COLD/AGM, 6V NORM, and 

12V LITHIUM.  Some charge modes must be pressed 

and held for three (3) seconds to enter the mode. These 

“Press and Hold” modes are advanced charging modes 

that require your full attention before selecting.  “Press 

and Hold” are indicated on the charger by a red line. It is 

important to understand the differences and purpose of 

each charge mode. Do not operate the charger until you 

confirm the appropriate charge mode for your battery. 

Below is a brief description:

1.800.456.6626
[email protected]
30339 Diamond Parkway, #102
Glenwillow, OH 44139
United States of America

Phone:

Email:

Mailing Address:

Summary of Contents for Genius G1100

Page 1: ...ot available in all areas visit www no co connect What s In The Box G1100 Smart Charger 1 Battery Clamp Connectors 1 Eyelet Terminal Connectors User Guide Information Guide and Warranty User Guide G1100V2 0 PRIOR TO USE READ AND UNDERSTAND PRODUCT SAFETY INFORMATION Failure to follow the instructions may result in ELECTRICAL SHOCK EXPLOSION or FIRE which may result in SERIOUS INJURY DEATH DAMAGE T...

Page 2: ...behind the mounting surface It is important to keep in mind the distance to the battery The DC cable length from the charger with either the battery clamp or eyelet terminal connectors is approximately 75 inches 1 900mm Allow for 12 inches 304mm of slack between connections Charging Modes The G1100 has five 5 modes Standby 12V NORM 12V COLD AGM 6V NORM and 12V LITHIUM Some charge modes must be pre...

Page 3: ...d an orange LED will illuminate For charging 12 volt Wet Cell Gel Cell Enhanced Flooded Maintenance Free and Calcium batteries When selected a white LED will illuminate For charging 12 volt batteries in cold temperatures below 50ºF 10ºC or AGM batteries When selected a blue LED will illuminate For charging 6 volt Wet Cell Gel Cell Enhanced Flooded Maintenance Free and Calcium batteries When select...

Page 4: ...E LITHIUM BATTERY MANUFACTURER BEFORE CHARGING AND ASK FOR RECOMMENDED CHARGING RATES AND VOLTAGES SOME LITHIUM ION BATTERIES MAY BE UNSTABLE AND UNSUITABLE FOR CHARGING MAKE SURE YOU PURCHASE YOUR LITHIUM ION BATTERY FROM A WELL KNOWN AND REPUTABLE BRAND Connecting to the Battery Do not connect the AC power plug until all other connections are made Identify the correct polarity of the battery ter...

Page 5: ...ltage and chemistry of the battery 2 Confirm that you have connected the battery clamps or eyelet terminal connectors properly and the AC power plug is plugged into an electrical outlet 3 The charger will begin in Standby mode indicated by an orange LED In Standby the charger is not providing any power 4 Press the mode button to toggle to the appropriate charge mode press and hold for three second...

Page 6: ...in the 100 Charge LED will turn solid green The charger can be left connected to the battery indefinitely 75 Orange LED The 50 Charge LED will slowly pulse on and off when the battery is less than 50 fully charged When the battery is 50 charged the red Charge LED will be solid The 75 Charge LED will slowly pulse on and off when the battery is less than 75 fully charged When the battery is 75 charg...

Page 7: ...tial Error Condition except reverse polarity and low voltage battery Error Reason Solution Single Flash Battery will not hold a charge Have battery checked by a professional Possible battery short Have battery checked by a professional Battery voltage is too high for the selected charge mode Check the battery and charge mode Error LED Solid Red Reverse polarity Reverse the battery connections Batt...

Page 8: ...en circuits short circuits and overheating Fast Charges two times faster than traditional battery chargers Compensation Adjusts for varying A C line voltage for consistent charging Rugged Dirt water UV impact and crush resistant Compact High frequency energy conversion for ultra compact lightweight and portable charger Start Stop Counteracts increased cyclic energy demands placed on batteries in m...

Page 9: ...nimizes energy consumption when full power is not needed Load Tracking Charge LEDs dynamically track the batteries state of charge when a load outpaces the charge current Diagnostics Intuitive visual diagnostic tool for detecting reverse polarity low voltage or damaged batteries CANBUS Automatically enables the charging port to charge CANBUS systems Thermal Monitor Internal temperature sensors adj...

Page 10: ...he charging process with a gentle soft charge Step 5 Bulk Begins the Bulk charging process based on the condition of the battery and returns 80 of the battery s capacity Step 6 Absorption Brings the charge level to 90 by delivering small amounts of current to provide a safe efficient charge This limits battery gassing and is essential to prolonging battery life Step 7 Optimization Finalizes the ch...

Page 11: ...The battery charger can be safely left connected indefinitely without the risk of overcharging Charging Times The estimated time to charge a battery is shown below The size of the battery Ah and its depth of discharge DOD greatly affect its charging time The charge time is based on an average depth of discharge to a fully charged battery and is for reference purposes only Actual data may differ du...

Page 12: ...V Maintains All Battery Sizes IP65 Natural Convection 6 02 x 2 5 x 1 5 Inches 0 81 Pounds Input Voltage AC Working Voltage AC Efficiency Power Charging Voltage Charging Current Low Voltage Detection Back Current Drain Ambient Temperature Charger Type Type of Batteries Battery Chemistries Battery Capacity Housing Protection Cooling Dimensions L x W x H Weight Technical Specifications ...