COOLING MODE 

Press ON/OFF button to turn the appliance on.
Press MODE button to select COOLING mode.
Set the temperature with INCREASE/DECREASE  buttons.
To select fan speed, press 

The set temperature will remain displayed in the control panel.

FAN SPEED  button repeatedly until the required speed is selected

(High/Med/Low/Auto).  Auto fan speed adjusts the fan speed automatically between HIGHMEDIUM
and LOW settings according to the variance between set temperature and room temperature.

NB: In 

NB:

COOLING mode, the appliance automatically removes excess moisture from the atmosphere.

In COOLING mode, the exhaust hose must be connected to allow warm air to be expelled from the room being cooled.

DRY (DEHUMIDIFYING) MODE 

Keep the windows and doors closed for an effective dehumidification.
When used as dehumidifier only, keep the air exhaust hose disconnected from the back of the unit
Press

Compressor light will be permanently illuminated in this mode after approximately 3 minutes.

ON/OFF button to turn the appliance on.

Press MODE button to select DRY mode, the fan speed will always be at Auto and can not be

adjusted in DRY mode and the control panel will display “dh”.

FAN MODE 

Press ON/OFF button to turn the appliance on
Press MODE button to select FAN mode.
To select fan speed, press FAN SPEED  button repeatedly until the required speed is selected (HIGH, 

MED, LOW ). The fan speed AUTO can not be selected in FAN mode.

NB: In FAN  mode, the exhaust hose does not need to be connected.

SETTING THE TIMER 

This timer can be used to delay the appliance start up or shutdown. This avoids wasting electricity by optimizing
operating periods.

PROGRAMMED SHUTDOWN 

With the appliance on, press TIMER button, the time remaining until shutdown is displayed on LCD.

 Set the time when you want the appliance to switch off with INCREASE and DECREASE buttons

(from 30 minutes to 24 hours).

During the first ten hours you can select half hour intervals. For times longer than ten hours, one hour

intervals can be selected.

Press TIMER button again to confirm the timer setting, the TIMER INDICATOR LIGHT lights up and
keeps flashing to indicate the timer is activated.
At the end of the set time the appliance switches off automatically.
To cancel the TIMER setting, press TIMER button again.

PROGRAMMED STARTUP 

Turn on the Appliance and select the required mode, for example, COOLING 25° C, fan speed HIGH.
Press ON/OFF button to switch into STANDBY.
Press TIMER button, the time is displayed on LCD display.
Set the time remaining until startup with INCREASE and DECREASE buttons, (from 30 minutes

to 24 hours).

During the first ten hours you can select half hour intervals. For times longer than ten hours one hour

intervals can be selected.

Press TIMER button again to confirm the timer setting, the TIMER INDICATOR LIGHT lights up and

keeps flashing to indicate the timer is activated. The time remaining (in hours) will also be shown

on LCD display.
At the end of the set time the appliance switches on automatically and operates in the selected mode,

for example COOLING 25°C, fan speed HIGH.

To cancel the TIMER setting, press the ” TIMER ” button again.

11

Summary of Contents for NC-49DC

Page 1: ...er manual carefully before using Any enquiries should be directed to NOBO on 1800 my nobo or 1800 69 6626 in the rst instance PORTABLE REFRIGERATED AIR CONDITIONER USER MANUAL For NC 49DP C NOBO 17 Br...

Page 2: ...r o f e b t e l t u o r e w o p e h t m o r f t i n u e h t g u l p n u s y a w l A filter cleaning Do not place the air conditioner or plastic window slider in direct sunlight For maximum cooling ef...

Page 3: ...duction 3 Installation 6 Control panel 10 Operation of control panel 10 Operation of remote control 12 Water drainage methods 14 Maintenance and service 15 Trouble shooting 17 2 NOBOCOOL NC 49DP C Spe...

Page 4: ...un and are the hottest in the house Rooms facing the morning sun East and away from the sun South are the coolest in the house 2 3 Air Draughts 4 Multi Storey Buildings Insulation Insulated roofs and...

Page 5: ...re In COOLING MODE once the existing room temperature reaches the set temperature the fan continues operating and the compressor switches on and off to maintain the set temperature within the room For...

Page 6: ...djusted air fins 3 Air outlet 4 Left Right auto air swinging fins 5 Rolling castor 6 Cable power cord and plug BACK Fig 2 1 Hot air outlet grill 2 Low air inlet grill 3 High air inlet grill 4 Power co...

Page 7: ...tlets cannot be covered up Place the unit no less than 50cm away from a wall or other obstacle INSTALLATION ACCESSORIES 6 5 0 c m 50cm Fig 3 user manual remote control batteries 50cm clearance at back...

Page 8: ...care to not break the tabs on the window adaptor when disconnecting from the window slider MOUNTING OF ASSEMBLED AIR EXHAUST HOSE Fig 5 Take care not to damage the hose inlet when attaching detatchin...

Page 9: ...king This will ensure maximum cooling output Never move the appliance by pulling the air exhaust hose attached to the back of the appliance Do not move the air conditioner when it is operating Correct...

Page 10: ...e to install Please refer to illustration for minimum and maximum window openings Additional complete window kits may be purchased from NOBO to enable pre installation in windows in other rooms Insert...

Page 11: ...perating R DRY MODE LIGHT illuminated when in DRY mode S COOLING MODE LIGHT illuminated when in COOLING mode OPERATION OF CONTROL PANEL The operating temperature ranges for cooling and dehumidifying a...

Page 12: ...e does not need to be connected SETTING THE TIMER This timer can be used to delay the appliance start up or shutdown This avoids wasting electricity by optimizing operating periods PROGRAMMED SHUTDOWN...

Page 13: ...remote control expose it to direct sunlight or leave it near sources of heat COOL DRY FAN HIGH MED LOW SWING TIMER ON TIMER OFF MODE FAN SWING ON OFF TIMER AUTO TIMER selection MODE selection FAN spe...

Page 14: ...longer than ten hours one hour intervals can be selected Press the TIMER button again to confirm the timer setting the TIMER INDICATOR LIGHT lights up and keeps flashing to indicate the timer is acti...

Page 15: ...upwards from the front until no more water drains from the outlet This air conditioner is equipped with the very latest MIST technology which means that the water tank does not have to be emptied This...

Page 16: ...ty of the unit Clean the surface of the unit with a damp cloth then dry with a duster or similar CLEANING THE AIR FILTER Clean the dust filter once every two weeks of operation This will keep the air...

Page 17: ...nto the drain pan and dispose of the water Tilt the unit by lifting it at the front to ensure all water is removed from the water tank Then operate the unit in fan mode for half a day until the pipe i...

Page 18: ...ter turning on Is timer on Wait for timer to count down or cancel timer setting by pressing Is compressor light illuminated Wait 3 minutes from turning on safety device prevents compressor which provi...

Page 19: ...isplayed contact Nobo on 1800 my nobo or 1800 69 6626 Ft FULL TANK The water tank is full Empty the internal tank see the section on Water Drainage Method This is a fail safe display due to protect ag...

Reviews: