background image

ASSEMBLY OF EXHAUST HOSE, HOSE INLET, HOSE OUTLET, WINDOW ADAPTOR
AND WINDOW SLIDER (Fig. 4)

•  Extend each end of the exhaust hose by about 8cm and attach the hose inlet and hose outlet to

opposite ends by rotating the inlet/outlet in a counter clockwise direction approximately 3 to 4 turns, making sure
that the hose wire is well threaded into the hose inlet and outlet.

•  Attach the window adaptor to the hose outlet by pressure fit.
•  Clip the window adaptor into the window slider. Take care to not break the tabs on the window

adaptor when disconnecting from the window slider.

MOUNTING OF ASSEMBLED AIR EXHAUST HOSE

(Fig. 5)

•  Take care not to damage the hose inlet when attaching/detaching  at the back of the Air Conditioner.
•  Slide the hose inlet (square end) in the direction indicated by the arrow onto the fixing lugs on hot air outlet 

grill at the back of the appliance. Install carefully and do not force.

•  Place the hose outlet to the nearest window. The length of the air exhaust hose is between 600mm

to 1500mm; use the minimum length when working.

•  When mounting, try to keep the air exhaust hose horizontal and do not extend its length by attaching

it to another hose as this reduces the cooling efficiency of the appliance.

Fig. 17

Fig. 5

6

Fig. 4

window 
slider

window 
adapter

hose 
outlet

hose hose 

inlet

NOBOCOOL NC-42CP/C

Summary of Contents for NC-42CC

Page 1: ...RTABLE TYPE AIR CONDITIONER USER MANUAL For Thank you for selecting our quality air conditioner Please be sure to read this user manual carefully before using Enquiries should be directed to Nobo on 1...

Page 2: ...share the power supply outlet with other appliances Do not rest hot or heavy objects on the appliance Always unplug the unit from the power outlet before cleaning or maintenance operations for example...

Page 3: ...ENTS Introduction 3 Installation 5 Control panel 9 Operation of control panel 9 Operation of remote control 11 Water drainage methods 13 Maintenance and service 14 Trouble shooting 16 2 NOBOCOOL NC 42...

Page 4: ...t designed to cool large open areas Close all doors and windows in the room being cooled Do not place the air conditioner in direct sun light Close all curtains in the room being cooled For maximum co...

Page 5: ...Air outlet 4 Left Right auto air swinging fins 5 Rolling castor 6 Cable power cord and plug BACK Fig 2 1 Hot air outlet grill 2 Low air inlet grill 3 High air inlet grill 4 Power cord hooks 5 Water ta...

Page 6: ...rtable air conditioner in a flat location where the air inlets and outlets cannot be covered up Place the unit no less than 50cm away from a wall or other obstacle INSTALLATION ACCESSORIES 5 5 0 c m 5...

Page 7: ...window slider MOUNTING OF ASSEMBLED AIR EXHAUST HOSE Fig 5 Take care not to damage the hose inlet when attaching detaching at the back of the Air Conditioner Slide the hose inlet square end in the dir...

Page 8: ...lling the air exhaust hose attached to the back of the appliance Do not move the air conditioner when it is operating Correct exhaust hose mounting shown below If mounting in the wall the height of th...

Page 9: ...require the use of cardboard fillers and or duct tape to install Please refer to illustration for minimum and maximum window openings Insert Altitude unlimited drawing here awning window and sliding...

Page 10: ...LING mode OPERATION OF CONTROL PANEL The operating ranges for cooling and dehumidifying are 18 C 32 C If the appliance is turned off during cooling or dry operation and restarted immediately the unit...

Page 11: ...e does not need to be connected SETTING THE TIMER This timer can be used to delay the appliance start up or shutdown This avoids wasting electricity by optimizing operating periods PROGRAMMED SHUTDOWN...

Page 12: ...iver Do not drop remote control expose it to direct sunlight or leave it near sources of heat COOL DRY FAN HIGH MED LOW SWING TIMER ON TIMER OFF MODE FAN SWING ON OFF TIMER AUTO TIMER selection MODE s...

Page 13: ...hour intervals can be selected Press the TIMER button again to confirm the timer setting the TIMER INDICATOR LIGHT lights up and keeps flashing to indicate the timer is activated At the end of the se...

Page 14: ...lifting it slightly upwards from the front until no more water drains from the outlet This air conditioner is equipped with the very latest MIST technology which means the water tank never fills This...

Page 15: ...n the surface of the unit with a damp cloth then dry with a duster or similar CLEANING THE AIR FILTER Clean the dust filter once every two weeks of operation This will keep the air conditioner working...

Page 16: ...nd dispose of the water Tilt the unit by lifting it at the front to ensure all water is removed from the water tank Then operate the unit in fan mode for half a day until the pipe is dry Wind the cabl...

Page 17: ...timer on Wait for timer to count down or cancel timer setting by pressing Is compressor light illuminated Wait 3 minutes from turning on safety device prevents compressor which provides cooling being...

Page 18: ...When the appliance is operating in dehumidifying mode this device prevents the formation of ice The appliance starts up again automatically when the defrosting process is complete PF PROBE FAILURE Sen...

Reviews: