OPERATION
20
Nobles SpeedGleam 5 / 7 (01- 2014)
4. Using a small standard screwdriver, turn the dial to
the appropriate battery type according to the
following chart (Figure 34).
NOTE:
The “0” position is only used when machine is
programmed at the factory or when the Software
Installation kit is used. Once the setting is changed from
“0”, it should not be changed back to “0” unless machine
is reprogrammed with the software installation kit
otherwise battery damage may result.
FIG. 34
Dial
Position
Battery Description Settings
0
Factory and Software Kit Setting
1
Wet, Trojan 180- 250 AH
2
Wet, Trojan 260- 360 AH
3
Wet, Enersys 200- 350 AH
4
AGM, Discover 200- 300 AH
5
AGM, Fullriver 200- 350 AH
6
Gel, Sonnenschein 150- 250 AH
4. Re- apply the display label.
5. Replace the control console.
6. To set the BDI to the new battery type, plug the
on- board battery charger cord into an electrical
outlet.