OPERATION
Power Eagle
t
716 (08--05)
11
2. Pull valve T--handle to empty dirty water
(Figure 10).
FIG. 10
3. Close valve before continuing operation.
DRAINING LEFTOVER CLEANING SOLUTION
1. When finished cleaning, use clean-out hose to
vacuum remaining water from solution tank.
Attach one end to recovery dome. Turn on Master
switch and use other end to vacuum water
(Figure 11).
FIG. 11
MACHINE MAINTENANCE
To keep machine in good working condition, simply
follow machine’s daily and monthly maintenance
procedures.
WARNING: Electrical Hazard. Unplug power
Cord Before Servicing Machine.
Contact an Authorized Service Center for machine
repairs.
FOR SAFETY: When servicing machine, all repairs
must be performed by a qualified service person.
DAILY MAINTENANCE
(After Every Use)
1. Drain and rinse out tanks thoroughly (See Draining
Tanks).
2. Rinse out recovery tank and recovery dome
thoroughly after every use.
3. Remove vacuum screen and clean (Figure 12).
FIG. 12
4. Remove and rinse off the two tank screens
located in the bottom of the solution tank.
5. Remove any entangled carpet fibers and debris in
brush.
6. Remove any clogged debris in vacuum head.
7. Check power cord for damage, replace if
necessary. Coil cord neatly after each use.
If the supply cord is damaged or broken, it must
be replaced by the manufacturer or it’s service
agent or a similarly qualified person in order to
avoid a hazard.
8. Inspect spray pattern for plugging. If plugged,
remove spray tips and soak in acetic acid solution
for up to six hours. Do not use pointed objects to
unplug tips, damage will occur.
FOR SAFETY: When using machine, follow mixing
and handling instructions on chemical containers.
9. Clean machine with a nonabrasive, nonsolvent
cleaner.
ATTENTION: Do not power spray or hose off
machine. Electrical component damage may
result.