2
Thank you for choosing our pallet trucks. For your safety and correct operation, please carefully
read the manual before use.
NOTE:
All of the information reported herein is based on data available at the time of printing. The
factory reserves the right to modify its own products at any time without notice or liability in any
sanctions. Please verify with the factory for possible updates and changes .
1. GENERAL SPECIFICATIONS
Capacity (kg)
2000
Maximum Fork Height (mm)
190
Minimum Fork Height (mm)
75
Fork Length (mm)
1150 / 1220
Width Overall Forks (mm)
520 / 550 / 685
Individual Fork Width (mm)
150
Load Wheel Diameter (mm)
Ø 74x55(or Ø 74x70) Nylon, Polyurethane
Steering Wheel Diameter (mm)
Ø 180)Nylon, Polyurethane, Rubber
Special fork lengths are available in 800, 900, 950, 1000mm.
Materials and specifications are subject to change without notice.
2. ATTACHING HANDLE TO PUMP UNIT
If you have purchased a wooden box of pallet truck, some assembly is required. Certainly, you need
some tools, a hammer, a pliers, a spanner, etc; and some parts, one axle with hole (66), one elastic
pins (68), these parts are putted in a plastic bag, which is putted into the draw-bar.
NOTE: The number of draw-bar and pump should be the same.
When attaching the handle, you had better squat just behind the pallet truck. Then you:
2.1
Insert the draw-bar onto the pump piston (60)
,
then use a hammer to insert the axle with hole
(66) into the hydraulic pump and draw-bar.
2.2
Let control handle(8) to the ‘
LOWER
’ position, then pass the adjusting nut(15), adjusting bolt(14)
and chain(12) through the hole of axle(66) with your hand.
2.3
Press the draw-bar (10) down, take away the pin, which fix the spring.
2.4
Let the control handle (8) on ‘
RAISE
’ position, then raise the lever plate (46) with the pin and
insert the adjusting bolt(14) into the front slot of lever plate (46), note to keep the adjusting nut
(15) on the under side of the lever plate.
2.5
Use a hammer to tap the elastic pin (106) into the axle with hole (66).
The draw-bar is now assembled to the pump.