Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP”

    

27 

ENGLISH

ENGLISH

OPERATING PROCEDURE:

 MENU >> SET USER >> CHANNELLING

Access the menu by pressing key
Scroll the items to SET USER with the key  
Access the menu by pressing key
First item in the “CHANNELLING” menu, key
The screen appears with setting of channelling, 

as in the figure.

OK

OK

OK

OK

Confirm with key  

If the PS function is not set, the fan 

is always restricted by the power of 

the product.

- SET 

  MANUAL: 

allows you to edit the power 

of channelling, keys:

  0  -  ventilation disabled;

1-7 -  setting range;

 PS -  ventilation follows 

         power to the fireplace 

         set on the appliance.

- ENABLE 

  TEMPERATURE 

  CONTROL: 

enables modulation of the 

ventilation once 

the setting has been reached;

OK

Enable/disable with the key           

-- SET  SETTING: 

allows you to edit the ambient 

temperature setting you want to 

reach in the channelled ambient.

Pressing the keys             

to enable/disable the 

flag if you want to man

-

age the temperature of 

the zone to channel with 

the help of the external 

thermostat.

(not supplied). Key        to 

confirm.

Press the keys 

to set the  

temperature of the 

zone to channel with 

the help of an optional 

ambient probe, 

provided on request of 

Nobis s.r.l.

(not supplies as standard)

OK

If the flag is enabled for “channelling” temperature 

management with the external thermostat, it is not 

possible to change the temperature setting from the 

handheld device, but rather from the external ther-

mostat.  

12.2 SET CHANNELLING TIMER

In the THERMOSTAT TIMER menu, for models with 

channelling, you can set the channelling power 

(ventilation speed) and the temperature you want to 

obtain in the room where the ventilation outlet is in-

stalled. Having set all the values relating to 

programmed switch on of the appliance, the follow-

ing screen appears.

Setting the ambient temperature for  

channelling, this is only managed if the TEMPERA-

TURE CONTROL function is enabled, previously seen, 

ENABLE T.EXT in SET SETTING disabled in the CHAN-

NELLING menu. 

Edit the data highlighted using the keys

Confirm the data changed using the key

Repeat the same operation to set the next param-

eter;

To return to the STAND-BY screen, use the 

key       , confirming all the settings.

OK

OK

12.3 DISPLAY CHANNELLING STATUS

To display the channelling status, from the STAND-BY 

status, press the key       .

The display screen follows:

SET 

CHANNELLED 

AMBIENT

TEMP. 

CHANNELLED 

AMBIENT

SPEED 

VENTILATION

OR

OK

Summary of Contents for A10C ROUND

Page 1: ...EN Installation use and maintenance manual A8 V C ROUND TOP A10 V C ROUND TOP...

Page 2: ...appropriate place having carefully consulted it Improper installation maintenance not carried out correctly and improper use of the product relieve the manufacturer of any liability towards people or...

Page 3: ...er 16 7 2 Description handheld device keys 16 7 3 Description handheld device display 16 7 4 Flat battery signalling 17 7 5 Concise icons diagram 17 8 Menu browsing 18 9 First start up instructions 18...

Page 4: ...ctivity and maintenance of safety devices do not remove or bypass this devices 1 3 IMPROPER USE The product must be intended for the use for which it was expressly designed for any other use the manu...

Page 5: ...careless use wrong maintenance non conforming installation with that specified by the manufacturer refer to the installation and use manual supplied with the appliance further damage caused by wrong i...

Page 6: ...making it less comfortable and reducing the overall efficiency of the system Hermetic prod ucts can also be installed in the presence of forced ventilation or in premises which can go into negative pr...

Page 7: ...r rooms garage etc and must have a net useful section equal or higher than 80 cm2 pellet burning stoves and thermostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not necessary for i...

Page 8: ...In Italy only roof discharge is permitted 3 4 CHIMNEY STACK The standard UNI 10683 states the stack must meet the following characteristics the smoke outlet section must be at least double the inner s...

Page 9: ...ble parts such as wood etc In both cases insert adequate insulation 5 be tween the chimney flue and the attic You are advised to check and comply with the plate data of the chimney flue in particular...

Page 10: ...G THE PRODUCT Packaging is composed of box es in recyclable cardboard ac cording to the RESY standards and wooden pallets All pack aging materials can be re used for similar use or if necessary dis po...

Page 11: ...th of the fan Reassemble the product and once powered go to USER SETUP SETTINGS CANALIZATION and choose the setting SINGLE to take advantage of canalization see menu dedicated to canalization infollow...

Page 12: ...stat function refer to the specific chapter in the following pages of this manual LOWER FRONT MAJOLICA ASSEMBLY Open the door that hides the ash drawer and re move the lower front majolica and 4 screw...

Page 13: ...echnician should completely and accurately clean the smoke pipes check the sealing status of all the gaskets remove broken pellet residue inside the pellet tank re assemble all parts of the appliance...

Page 14: ...EN 22768 mK NOBIS S r l N DISEGNO MATERIAL DESIGNER DATE DRWG NR CHECKED WEIGHT Via Palazzolo 11 25037 Pontoglio BS Italy P iva e Cod Fisc 04222670160 S MATERIA PRIMA RAW MATERIAL 80 smoke discharge...

Page 15: ...loaded by inserting pellets from the upper part of the product opening the door Ensure the content of the bag of pellets does not fall around the edges of the tank paying particular attention to centr...

Page 16: ...hapter carefully relating to use of the receiver and the handheld device as well as their related functions INFORMATIVE NOTE frequency bands and transmitted power used by the equipment as reported in...

Page 17: ...appliance see Concise icons diagram 7 4 FLAT BATTERIES SIGNAL If batteries are flat the display presents a symbol which indicates their limit status however maintaining the functions enabled of the ha...

Page 18: ...l the items to SETTINGS with the key Access the menu by pressing key Scroll the items to TIME DATE with the key On the TIME DATE menu item key The screen appears to adjust the time and calendar as in...

Page 19: ...its manual management of the op tional fan with the exception of the fan setting on OFF In this case the appliance autonomously only manages power to the fireplace Ventilation remains disabled 9 5 FIR...

Page 20: ...ode also en sures if the home has a good energy class a fuel saving through intelligent switch off of the product reaching or required of the desired setting The procedure follows to enable the functi...

Page 21: ...Y screen use the key repeating the operation multiple times OK OK Edit the value with the keys The logic relating to this type of management is as follows USER the user reserves the right to set the a...

Page 22: ...ostat with timer function you can program for each day of the week automatic switch on and off of the product with 4 independent time intervals PROGRAM 1 2 3 4 The steps are outlined below to follow s...

Page 23: ...switch on phase of the appliance after accurate cleaning was conducted of the hopper pellet con tainer to remove sawdust which over time is creat ed on the base See the chapter Routine mainte nance o...

Page 24: ...and 3 EXTRACTION was set this kind of setting results from the fact combustion is lacking oxygen and the pellets are small in size compared to the average 2cm OK Select the type of screen you want to...

Page 25: ...installed has not yet reached the temperature required the writing T OFF if in the room the ambient temperature is reached 11 6 LANGUAGE Based on the destination country or the user acquir ing the pro...

Page 26: ...ply approach the appliance to re establish communication 12 CHANNEL where planned The products of the range equipped with channel ling are in two types single duct channelling or double duct channelli...

Page 27: ...channel with the help of an optional ambient probe provided on request of Nobis s r l not supplies as standard OK If the flag is enabled for channelling temperature management with the external thermo...

Page 28: ...setting from the handheld device but rather from the external ther mostat Having confirmed setting of the RH channelling confirm with the key and re peat the same sequence of operations for the LH cha...

Page 29: ...PHASE DESCRIPTION Ambient setting in MAN therefore the appliance only works with the power to the fireplace set never going to saving MAN WORK 14 FUNCTIONS CONCISE DIAGRAM Edit the data highlighted us...

Page 30: ...ntrolling correct combustion For safety purposes while waiting for the technician the appliance is set to saving mode The maximum smoke temperature threshold has been reached the appliance for a perio...

Page 31: ...ice ALARM CODE REASON 05 EXTRACTOR ROTATIONS NOT RESPECTED The rotations of the smoke extractor show a loss of efficiency due to obstruction of the fan or a drop in voltage SOLUTION If the problem per...

Page 32: ...ersists contact the Support Service ALARM CODE REASON 16 PELLET TANK DOOR OPEN During the pellet loading phase of the product the tank door was not closed properly SOLUTION Check the pellet tank door...

Page 33: ...are cold to touch ensure the combustion ash is completely out To clean the surfaces on the painted metal parts use a cloth soaked in water and soap Use of abrasive detergents or diluents causes damag...

Page 34: ...which could damage the appliance used for cleaning The cleaning operations depend on the quality of the pellets used and the frequency of use of the product It can happen that such operations must be...

Page 35: ...nsable for correct appliance operation PARTS FREQUENCY TIME Ash pan approx time 7 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD Chimney flue 1 SE C...

Page 36: ...ET THERMAL SWITCH CONTACT DOOR ASH PAN 1 PELLET TANK 2 220V SOCKET WITH ON OFF SWITCH AND FUSE SAFETY VACUUM SWITCH VENTILATION FRONT K J PC CONNECTION technical support only USB CONNECTION technical...

Page 37: ...Use and Maintenance Manual model A8 A10 V C ROUND TOP 37 ENGLISH MAINTENANCE DATE INTERVENTION CARRIED OUT...

Page 38: ...Use and Maintenance Manual model A8 A10 V C ROUND TOP 38 ENGLISH NOTE...

Page 39: ......

Page 40: ...N 11 25037 Pontoglio BS www nobisfire it Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products without prior warnin...

Reviews: