background image

3

PARTS LIST

ITEM 

NO.

PART NAME

DRG NUMBER

Size (inch)

IMAGE

QTY.

1

S1C Frame

S1C

78.74 x 40.74

6

2

CB1 Bracket

CB1

4.3 x 4.3 x 1.57

6

3

JF1 Bracket

JF1

4.33 x 1.57

6

4

ST1 Roof Tie

ST1

40.35

2

5

40x40 End cap

EC40

1.6 X 1.6

4

6

FT1 Bracket

FT1

1.57 x 1.57 x 3.94

4

7

FT3 Bracket

FT3

1.57 x 3.15 x 4.17

4

8

DR Bracket

DR

4.3 x 1.6 x 2

12

9

AR1R  1m Pitch Rafter

AR1R

45 x 11.8 OA

4

10

AR1IS  1m Pitch Infill 

Panel Shallow

AR1IS

45.2 x 13.5

2

11

AR1CLTO  1m Apex 

Roof Centre Lower 

Trim Outer

AR1CLTO

41.4

2

12

AR1CLTI  1m Apex 

Roof centre lower trim 

inner

AR1CLTI

40.74

1

13

Roof F Section Outer

ARFSO

41.5

4

14

ARFSI  Apex Roof F 

Section Inner

ARFSI

40.75

2

15

AR1POA  Roof Panel 

outer alu

AR1POA

41.5 x 24.4

4

16

AR1PIA  Roof Panel 

inner ALU

AR1PIA

40.75 x 24.4

2

17

AR1TS  1m Apex Roof 

Trim strips

AR1TS

24.8 x 2.3

4

18

AR1CUTO  1m Apex 

Roof centre upper trim 

outer

AR1CUTO

41.5

2

19

AR1CUTI  1m Apex 

Roof centre upper trim 

inner

AR1CUTI

40.75

1

Summary of Contents for SR8060-F

Page 1: ...Assembly Instructions Shelter type SR8060 F SR8060F 01 02112021 USA Email Sales nobutts com Web www nobutts com Tel 1 888 662 8887...

Page 2: ...10 10 18 19 18 17 7 6 6 6 6 2 2 1 3 17 15 16 15 2 3 3 2 1 4 4 8 8 8 9 11 12 13 11 13 13 14 5 2 Exploded view Tools required Drill Screwdriver Mallet 17mm Wrench T25 Torx bit...

Page 3: ...11 8 OA 4 10 AR1IS 1m Pitch Infill Panel Shallow AR1IS 45 2 x 13 5 2 11 AR1CLTO 1m Apex Roof Centre Lower Trim Outer AR1CLTO 41 4 2 12 AR1CLTI 1m Apex Roof centre lower trim inner AR1CLTI 40 74 1 13 R...

Page 4: ...4 FIXINGS Fittings Bolt set M10 T25 T38 BTANCM12100 M10 x 60mm Nut Washer 1 Tech screw 1 5 mm Tech screw Black Caps M10 12 x 100 mm Concrete Bolt Pack A B 33 33 66 136 40 66 11 Image...

Page 5: ...TO CHECK CORRECT ALIGNMENT JF1 Please note 1 5 Tec Screws are for roof panels only JF1 JF1 CB1 CB1 JF1 JF1 ENSURE CORRECT ALIGNMENT ON CORNERS Step 1 Assemble S1C frames to make up the main structure...

Page 6: ...ST1 CB1 JF1 CB1 ST1 JF1 S1C CB1 CB1 JF1 JF1 ST1 ST1 S1C Step 2 Use JF1 and CB1 brackets to attach the S1C frame and ST1 Tie bars 6...

Page 7: ...NSURE CORRECT ALIGNMENT OF RAFTERS AND S1 FRAMES END PANEL END PANEL Step 3 Attach AR1R rafters using DR brackets Secure the AR1IS end panels to S1 frames using 1 tec screws The end rafters need to be...

Page 8: ...ALE 1 2 8 Attach the AR1CLTO and AR1CLTI to the top of the rafters The AR1CLTO are to be lined up near the end panels and the AR1CLTI have to be spaced centrally The ARFSO and ARFSI parts are to be at...

Page 9: ...5 Attach the AR1POA roof panels on the outer edges of the shelter nearest to the end panels and the AR1PIA pannels need to be equaly spaced along the centre Cap off the top using AR1CUTO and AR1CUTI a...

Page 10: ...45 3 123 98 PLAN VIEW OVERALL DIMENSIONS AND GROUND FIXING POSITIONS Suggested size for concrete base 8inch oversized on all 4 sides...

Page 11: ...anels regularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS No Butts Bin Company Inc 16 Birch Lane M...

Reviews: