background image

3

PARTS LIST

ITEM NO. PART NO.

DESCRIPTION DIMENSION 

(MM)

DIMENSION 

(INCHES)

IMAGE

QTY.

1

S1C

Frame

2000 x 1035 78.74 x 40.55

9

2

CB1

Bracket

110 x 110

4.33 x 4.33

8

3

JF1

Bracket

220 x 40

8.66 x 1.58

12

4

ST3 

Roof Tie

2060 x 40 x 

40

81.10 x 1.57 x 

1.57

1

5

P1

Post

2000 x 1030 78.74 x 40.55

1

6

FT1 

Foot Bracket 109 x 100 x 

40

4.29 x 3.93 x 

1.57

3

7

FT3 

Foot Bracket 109 x 100 x 

80

4.29 x 3.93 x 

3.27

8

8

RB1

Bracket

110 x 46

4.33 x 1.81

16

9

R2

Rafter

2200 x 40 x 

40

87.40 x 1.57 x 

1.57

5

10

SS

Sealing Strip Trim To 2195 Trim To  86.61

4 ROLLS

11

PCE2

Roof Panel 2200 x 1050 87.40 x 41.34

2

12

PCC2

Roof Panel 2200 x 1030 87.40 x 40.55

2

13

RC2

Roof Strip

2200

87.40

5

14

2MD

Roof Edge 

Trim

Trim To Fit

Trim To Fit

5

15

EC40

Plastic End 

Cap

40 x 40

1.57 x 1.57

24

Summary of Contents for SR1556-F

Page 1: ...Assembly Instructions Shelter type SR1556 F SR1556 F 02 100119 USA...

Page 2: ...EXPLODED VIEW 13 12 11 9 10 5 7 6 14 8 3 1 2 4 2...

Page 3: ...40 55 1 6 FT1 Foot Bracket 109 x 100 x 40 4 29 x 3 93 x 1 57 3 7 FT3 Foot Bracket 109 x 100 x 80 4 29 x 3 93 x 3 27 8 8 RB1 Bracket 110 x 46 4 33 x 1 81 16 9 R2 Rafter 2200 x 40 x 40 87 40 x 1 57 x 1...

Page 4: ...Mallet Hack saw Spanner Torx bit Bolt set M10 Nut Washer Black Cap T25 T38 AB1210 M10 x 60 mm 25 mm Tech screw 38 mm Tech screw M10 12 x 100mm Concrete Bolt Pack A B 40 40 80 80 136 66 13 Required 21...

Page 5: ...B1 CB1 CB1 Ensure correct alignment on corners Step 1 Assemble S1C frames to make up the main structure using CB1 brackets for the corners and JF1 brackets for the straight joints 5 MEASUREMENTS IN BL...

Page 6: ...post using one JF1 bracket then attach ST3 tie bar using another JF1 bracket and two CB1 brackets Move the shelter to its final position make sure the structure is square and attach the FT1 and FT3 fo...

Page 7: ...R2 RB2 R2 RB2 40 75 40 75 40 75 40 75 1035 1035 1035 1035 FRONT VIEW Step 3 Use RB1 brackets to secure the R2 roof rafters 7...

Page 8: ...2 SS RC2 SS PCE2 PCC2 PCE2 Step 4 Apply sealing strips SS to the top of the rafters Align PCE2 roof panels with the outer rafters then space out the PCC2 panels evenly Cover the two edges along the ou...

Page 9: ...2MD 2MD Step 5 Clip on the 2MD end caps Then fit the Black plastic caps on exposed nuts and bolts Fit the square end caps to any open ends of box sections 9...

Page 10: ...035 1035 985 50 985 50 995 2048 50 1035 985 50 1035 1035 2180 33 40 75 40 75 80 65 39 17 38 80 40 75 38 80 40 75 40 75 40 75 38 80 161 04 85 84 164 57 10 Plan view Suggested size for concrete base 200...

Page 11: ...11 NOTES...

Page 12: ...anels regularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales nobutts com Web www nobutts...

Reviews: