Warranty Information 
 

 

NLR warrants to the original purchaser that the AMS-500 Controller Shall be free from defects 

in parts and workmanship under normal use for 6 months from the date of purchase. 
 
 

NLR obligation under this warranty is limited to the repair or replacement of any component 

found to be defective when returned postpaid to NLR. 
 
 

The Controller must be returned with evidence of place and date of purchase or warranty will be 

void. The warranty will not apply if the AMS-500 Controller has been installed incorrectly, repaired, 
damaged, or tampered with by misuse, negligence or accident. 

IMPORTANT

The AMS-500 controls the pressure on the Waste Gate so the actual 

boost level obtained is a combination of the Waste Gate Spring pressure and pressure 
applied by the controller 

www.nlrsystems.com or 

Phone 334-741-7100

 

NOTE—The AMS-500 Must be turned OFF and back ON when a change is made to any 
switch. If this is not done the new switch settings will be ignored until the next power 
on! 

Summary of Contents for AMS-500

Page 1: ...ressure increase and will dis able the system and open the decrease solenoid in the event of an error condition When in Normal Mode of operation the AMS 500 will keep trying to apply pressure to the w...

Page 2: ...ty or liability for damages incurred from the use of products manufactured or sold by NLR LLC on vehicles used for competition racing NLR LLC neither recommends nor approves the use of products manufa...

Page 3: ...sys tem When in Safe Mode the Red LED will flash 4 times at power up to indicate this mode is active Switching between modes of operation 1 Set all Stage1 and Stage2 switches to 0 including the Ramp...

Page 4: ...nput is activated first becomes the First Stage this Input may remain ON or OFF while the second Input is Activated The Stage1 2 Green LED s will blink four times at power up to indicate this mode is...

Page 5: ...Launch psi see Configure Stage1 Input1 Operating Mode for more information Setting Target Psi There are two Stage1 target psi programming switches These are used together to represent the target psi...

Page 6: ...ected using the Stage2 Ramp Rate Select Switch A setting of 0 will re sult in the target pressure being applied immediately when Stage2 is active See chart below for other Ramp Rates The Ramp Rates ar...

Page 7: ...Plug Air Supply or Manifold Pressure Wastegate Manifold Pressure 1 2 O N 0 56 7 8 9 1 2 3 4 0 56 7 8 9 1 2 3 4 0 56 7 8 9 1 2 34 0 56 7 8 9 1 2 3 4 0 1 2 3 4 5 6 789 A B C D E F MAP Sensor port 1 8 NP...

Page 8: ...e and date of purchase or warranty will be void The warranty will not apply if the AMS 500 Controller has been installed incorrectly repaired damaged or tampered with by misuse negligence or accident...

Reviews: