nLight nCM ADCX RJB Manual Download Page 4

Acuity Brands  |  One Lithonia Way  Conyers, GA  30012  Phone: 800.535.2465  www.acuitybrands.com/nLight

© 2014-2021 Acuity Brands Lighting, Inc.  All rights reserved.  Rev. 12/28/21

nCM ADCX (PC) RJB - TN-140-001

4 of 4

Electrical

Input Ratings

15-24VDC, 3mA, Class 2 (nLight network power)

Output Ratings

24 VAC/VDC, 1A - Resistive (AR option)

Relay Type

Latching (AR option)

Standards/ Ratings

Energy Management Equipment, UL916 (E167435)

Mechanical

Dimensions

4.55”W x 1.55”D (116mm x 40mm)

Mounting

Single-Gang or Octagonal Box, Surface Mount

Color

White

Finish

Matte

Connection Type

RJ-45 nLight Network Ports (2 ports via included RJ-45 splitter) 

Low-Voltage Leads (AR option) 

Environmental 

Warrantied Operating Temperature

Standard: 14°F to 185°F (-10°C to 85°C) 

LT option: -4°F to 185°F (-20°C to 85°C)

Relative Humidity

Up to 90%, Non-Condensing

Standards/ Ratings

RoHS

General

Standards/ Ratings

System Component to aid in compliance with Title 24, ASHRAE 90.1, IECC

SPECIFICATIONS

Summary of Contents for nCM ADCX RJB

Page 1: ...ions work standalone and do not require a connection to a larger nLight network FEATURES Automatic Dimming Photocell Control nCM ADCX RJB model only Full On Off Photocell Switching Control disabled by default on nCM ADCX RJB Optional Inhibit mode Photocell can prevent lights from turning on if adequate daylight is available but does turn lights off nCM PC RJB model only LED status indicator Adjust...

Page 2: ...ghting will be back at its full bright level ThenCMPCRJBsensordoesnotcontroldimming butinsteadsignalsnLightdeviceslocatedelsewherewithinthesensor szonetoswitchacontrolledlighting load on when more light is needed The lights are also signaled to turn off when light is above the set point plus a 10 safety factor and deadband The safety factor will prevent the system from cycling when the light level...

Page 3: ...Wiring an nCM PC RJB to an nLight Relay Pack Several operational settings for the nCM ADCX RJB and nCM PC RJB are available and configurable through the unit s push button and or SensorView software including Common Settings Photocell Broadcasting Enable Disable Photocell Broadcasting Channel 1 16 LED Indicator Enabled Disable Automatic Set point Calibration Mode Blink back Set point in footcandle...

Page 4: ...rgy Management Equipment UL916 E167435 Mechanical Dimensions 4 55 W x 1 55 D 116mm x 40mm Mounting Single Gang or Octagonal Box Surface Mount Color White Finish Matte Connection Type RJ 45 nLight Network Ports 2 ports via included RJ 45 splitter Low Voltage Leads AR option Environmental Warrantied Operating Temperature Standard 14 F to 185 F 10 C to 85 C LT option 4 F to 185 F 20 C to 85 C Relativ...

Reviews: