 General overview

Warning: 

Koheras HARMONIK lasers are Class 4 lasers. Before any operation is attempted, ensure the procedures and notices 

within this Installation Guide and the hazard labels on the product are read, noted, and adhered to. In addition, make sure to follow 
all safety recommendations listed in the 

Koheras HARMONIK Safety, Handling and Regulatory Information

 document shipped with 

your laser. If in doubt, consult your laser safety officer. 

Warning: 

Do not install the fiber coupler with the laser powered on. Ensure power to the laser is removed before proceeding with 

the installation.

Warning: 

Use of controls or adjustments or performance of procedures other than those specified herein and in the document 

Koheras HARMONIK Product Guide

 may result in hazardous radiation exposure.

Using four attachment bolts and washers, the fiber coupler 
flange adapter is bolted onto the front panel of the 
HARMONIK module. An iris diaphragm is used to coarsely 
align the adapter with the output beam. Coarse alignment 
is achieved by using a power meter to measure the 
transmitted power and then maximize it by laterally shifting 
the adapter. This ensures the adapter is accurately 
centered on the output beam. Once the coarse alignment 
is completed, the fiber coupler is inserted and fixed to the 
flange adapter and then finely adjusted.

Installation environment

It is important that the installation environment is clean and 
free from dust or other contaminants. Further, the output 
windows should be free from any dust particles before 
installation of the fiber couplers. 

Safety precautions

Align both the fundamental and second harmonic laser 
apertures using an appropriate beam dump. To further 
prevent damage and accidental exposure to personnel, 
ensure the beam path is safely contained and known.

All nearby personnel must wear suitable clothing and be 
aware of the laser operations and the danger involved.

Item list

1

Koheras HARMONIK

2

aeroGUIDE Power cable

3

Flange adapter 

4

Four M2x6 hex screws with washers

5

Fiber coupler for second harmonic and/or fundamental 
output

Tools required

1

Adjustable iris diaphragm

2

50HD-15 hex screw driver 

3

9D-12 screw driver

4

Eccentric key

5

Power meter

Removal of protection caps

To prevent contamination, the fiber couplers come with 
dust protection caps. Remove the caps before continuing 
the installation.