Introduction 

 

 

  

1.3

 

Pressure sensor 

The  pressure  sensor  is  a  piezoresitive  sensor  that  measures  absolute  pressure. 

That’s  means  the 

reference is vacuum. The sonde allows adding an offset to compensate the measured pressure with 
the current atmospheric pressure in order to get a zeroing of the pressure sensor. However zero will 
vary with changes in atmospheric pressure. 

The  sensor  contains  its  own  temperature  measurement  to  make  its  compensation.  Temperature 
measurement is available in the WiMo and WiMo Plus sondes. 

Number of locations
Operating environment
Maximum Depth
Communication

Weight

3,05 kg

Size

Diameter :

110 mm

Total length :

499 mm

WiFi / Modbus RTU

Power supply

External 9 - 16 VDC

Internal 6  alkaline batteries type D or 6  NiMh rechargeable batteries type D

Temperature 

Storage (no battery): -20°C à 70°C

Operating : - 2 à +50°C

WiMo Plus Sonde Specifications

7

Fresh and sea water

250 m

Universal 
Location 

Pressure 
sensor 

Wiper/sensor 
Location 

Handle 

Guard 

Wi-Fi 
Activation  

6 pin connector 

Summary of Contents for WiMo

Page 1: ...nke Instrumentation 6 rue Gutenberg ZI de Kerandr 56700 Hennebont France WiMo WiMo Plus User Manual Revision 1 3 09 03 22...

Page 2: ...protection guard 11 2 3 SONDE ACTIVATION 12 2 4 CONNECTION TO SONDE 12 2 4 1 PC 13 2 4 2 Tablet 13 2 4 3 Smartphone 14 3 WEB INTERFACE 15 3 1 DASHBOARD MENU 16 3 1 1 General settings 16 3 1 2 Storage...

Page 3: ...des 2 Table of contents 6 2 CSV FORMAT 27 6 2 1 Datas 28 6 2 2 settings 28 7 MANAGEMENT OF ALARM FILES 30 8 OPERATION WITH THE WIMO MODEM 31 8 1 FLOTTEUR WIMO 20 LITRES 32 8 2 BOUEE COTIERE WIMO 33 9...

Page 4: ...or real time measurement of the environment 1 1 WiMo Specifications The WiMo sonde has 4 universal locations where sensors or a cleaning system can be plugged The sonde is equipped with a pressure and...

Page 5: ...uipped with a pressure and temperature sensor It is powered by 6 Type D Alcaline batteries and is compliant with NiMH Type D rechargeable batteries A Wi Fi link is used to setup the sonde and for file...

Page 6: ...nsor contains its own temperature measurement to make its compensation Temperature measurement is available in the WiMo and WiMo Plus sondes Number of locations Operating environment Maximum Depth Com...

Page 7: ...and WiMo Plus sondes allow a cleaning device on their location This device is a smart wiper It self configures according to the sensors that are connected to the sonde It automatically detects whethe...

Page 8: ...on each sensor location These caps ensure the sonde is waterproof When you remove a cap the sonde is no longer waterproof until you place a sensor or a cap If the WiMo has been immersed in water you m...

Page 9: ...it Place it on a clean surface and store it taking care not to damage the O rings Before repositioning the cap check that the location in the sonde has no damage and no scratches Grease both O rings o...

Page 10: ...he sensor check that the location in the sonde has no damage and no scratches Grease the two sensor O rings with the supplied grease and engage it in the location by making the coded pin coincide with...

Page 11: ...handle it carefully to avoid damaging the coating To install the guard screws in clockwise direction To remove it you must unscrewed by turning in the anti clockwise direction If optical sensors are...

Page 12: ...r protection guard The protection supplied as standard with the WiMo and WiMoPlus probe does not properly protect the ISE sensors Redox Nitrate and Ammonium For optimal protection it is necessary to e...

Page 13: ...vation affix the magnet to the Wi Fi symbol Wait at least two seconds before removing it If the sound indication is enable when activated the sonde will beep continuously for one second 2 4 Connection...

Page 14: ...SSID is in the FORM of WIMO XXXX Select the sonde and click Connect 2 4 2 Tablet Once the sonde is activated see 2 3 search its SSID in the list of available networks by going into Wi Fi settings The...

Page 15: ...sonde is activated see 2 3 go to Wi Fi settings menu and search its SSID in the list of available networks The sonde s SSID is in the FORM of WIMO XXXX Select the sonde and click Connect Step N 1 Sel...

Page 16: ...n internet browser Chrome Edge Safari Enter the default address 192 168 56 1 in the address bar It will be possible in the sonde interface to modify this address if you want to protect access to your...

Page 17: ...estimate of battery life based on sonde settings 3 1 1 General settings When first using or changing the battery it is essential to set the sonde at the actual time in order to be able to switch to r...

Page 18: ...ZIP to save memory space 3 1 3 Network and communication Wi Fi network settings can be changed including the narrow bands used if they are cluttered To be able to communicate in Modbus with the sonde...

Page 19: ...meters 3 1 5 Connected accessories When a wiper is detected it appears in this topic The refresh accessories button also refreshes the sensors 3 1 6 Acquisition settings There are several sampling mod...

Page 20: ...to start stop recording manually on a parameter condition or on a specific date By clicking on this symbol present in Sampling regime you will see a schematic help window like the one below on the di...

Page 21: ...the DASHBOARD page is enabled Data files are measurement recorded in datalogger mode You can either download or delete the files one by one or all at once For data files information about the file is...

Page 22: ...rements Only enabled sensors on the DASHBOARD page appears in live view Measurements can be viewed analytically graphically or both The parameter is displayed or not simply by clicking once on the ass...

Page 23: ...l battery voltage monitoring It can generate and then transfer by Email an alarm file on detection of weak batteries All you have to do is activate the Low battery function The second level of detecti...

Page 24: ...ll sensors and accessories to the sonde Step N 2 Activate Wi Fi cf 2 3 and connect to the sonde cf 2 4 Step N 3 Open the communication interface cf 3 Step N 4 Check that all sensors have been detected...

Page 25: ...ater and rinse the sensor with fresh water Wipe and dry the sensor with a soft cloth or optical wipes 4 1 1 O rings service The O rings seal the probe Any O rings damaged can affect the reliability of...

Page 26: ...ries Step 1 Using allen keys provided unscrew the screws from the handle and then remove the handle Unscrew the two screws holding the cap Step 2 Put the dismount cap toolkit on the handle attachment...

Page 27: ...into the body Take care to check the state of o rings Use the Allen key to insert the two screws to lock the cap 5 Product Identification The WiMo is identified with a label summarizing its identifier...

Page 28: ...starts with a letter and can only contain letters underscores and dots Field 3 Data value File example 4a39_20200218111415 txt 200218111425 PRESSURE_01 0 079 200218111425 TEMPERATURE_02 19 90 2002181...

Page 29: ...file entire configuration used for data acquisition is inserted in XML format This part is used to display the information about the file in the interface but can also be used by the end user to find...

Page 30: ...ity eS1 Battery capacity SENSOR_X eS0 Sensor ID eS1 Manufacturer eS2 Sensor name CHANNEL_X eC0 Measurement channel name and type eC1 Unit eC2 Number of measurement precision digits eC4 Measurement mea...

Page 31: ...ble below lists the code of the alarms that are likely to be transmitted Code Commentaires I990 System power on information I991 External power supply presence information I992 Low internal temperatur...

Page 32: ...nd is compliant with French and foreign networks The modem once connected to a WIMO sonde is automatically detected The sonde is then able to set it up The modem retrieves files acquired by the WIMO a...

Page 33: ...Network and communication window Modem detection causes new elements to appear in the WEB interface specific to the modem Network and communication o GPS line Allows the activation and configuration...

Page 34: ...meter bellow the water surface The float has been designed to facilitate the extraction of the probe without tools and thus easily carry out the maintenance of the sensors The system supplied by nke i...

Page 35: ...ervice it is essential to follow the RMA procedure Any material returned without an RMA number will not be taken into account In case of shipment for repair or expertise obtain an RMA number by using...

Page 36: ...Mo Plus Multiparameters Sondes 35 Return a product to the factory nke Instrumentation 6 rue Gutenberg ZI de Kerandr 56700 Hennebont France Tel 33 2 97 36 41 31 Fax 33 02 97 55 17 www nke instrumentati...