连接接口

Specification

连接接口

Item

Description

Power

Power Supply

Power Adapter

Voltage Range

DC5V

Consumption

<5W

Ethernet Port

Ethernet Port

LAN Port:10/100Mbps

Transmission Distance

 LAN Port: 0~100m

Optical Port

Optical Port

Double Fiber SC Port

Wavelength

1310nm

Bandwidth

155Mbps

Transmission Distance

Single Mode: 20km; Multi-mode: 2km

Network Switch

Network Standard

IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX/FX

Status 

Indicator

Power LED

1 (Green)

Network LED

1 (Green) on the RJ45 socket

Optical LED

FED, SD, LINK 3 (Green)

Protection

ESD

Contact Discharge  6KV; Air Discharge 8KV

Environmental

Working Temperature

0 ~55℃

Storage Temperature

-40 ~85℃

Humidity (Non-condensing)

0~95%

Mechanical

Size (L×W×H)

83mm×90mm×25mm

Material

Aluminum Alloy

Color

Black

Weight

100g

Stability

MTBF

>30000h

连接接口

Trouble

 

Shooting

Product are subject to change without prior notice

3

4

Fast Ethernet  Converter

Fast Ethernet  Converter

Please find the following solution when the device doesn't work

Please confirm if the installation is correct;
Please confirm if the RJ45 cable order in accordance with the EIA/TIA568A or 568B industry 
standards;
The maximum transmission distance depend on the signal source and cable's quality, please don't 
exceed device's maximum transmission distance;
Please replace a normal device with a failure one to check if the device is broken;
If the problem still exist, please contact the factory. 

RJ 45 Making Method

Instruments to be used: wire crimper, network tester. Wire sequence of RJ45 plug should conform with 
EIA/TIA568A or 568B. 
1) Shuck off about 2cm long the insulating layer, and bar the 4 pairs UTP cable; 
2) Depart the 4 pairs UTP cable and straighten them;
3) Line up the 8 pieces of cables per EIA/TIA 568A or 568B;
4) Cut out 1.5 cm cable wrap and leave the bare wire;

) Plug 8 cables into RJ45 plug, make sure each cable is in each pin;

5
6) Then use wire crimper to crimp it;
7) Follow the 5 steps above to make the another end, following the same sequence of the first plug;
8) Using network tester to test the cable whether is working.

   pin    color

   

           white/green

                 green

                    blue

               white/orange

                white/blue

                white/brown

                    orange

             brown

1

2

3

4

5

6

7

8

 pin            color

1

2

3

4

5

6

7

8

   

           white/green

                   green

                   blue

               white/orange

                white/blue

                white/brown

                    orange

                   brown

EIA/TIA 568A

EIA/TIA 568B

Notice

When choose RJ-45 make sure if one end is EIA/TIA568B,the other end should also be EIA/TIA568B.

When choose RJ-45 make sure if one end is EIA/TIA568A,the other end should also be EIA/TIA568A.

Reviews: