Nixie Temp n Glow IN-16 User Manual Download Page 6

Temp’n’Glow IN‐16 Nixie Thermometer    Documentation 

 

 

 

6

4

 

=

 

Units

 

The display shows "4x", whereby the value x has the range from 1‐2

(factory setting) 

The values of x have the following meanings: 

 = The tubes show the temperature in the unit ° C 

 = The tubes show the temperature in the unit ° F 

1

2
 

as the range from 0‐1. 

5

 

=

 

CP

 

Prevention

 

x" whereby the value x h

ngs: 

The display shows "5

The values of x have the following meani

 = Prevention is off 

0
1 = CP Prevention is on (factory setting) 

 
If CP prevention is switched on, the Cathode Poisoning Prevention is executed every 5 minutes. 

This is done as follows: 

t tube and the right decimal dot of the right tube is 

The minus sign or the left decimal dot of the lef
switched on. 

The digits 0‐9 are scrolled through both tubes. 

uration of the scroll operation: 4 seconds 

fter having done that the display will show the temperatures again. 

D

A

 

5 Display 

limits 

I

 

f the (theoretical) temperature is below ‐99 or over +99 ° C or ° F the display still shows ‐99 to +99. 

6 Error 

indication 

If one of the sensor is not connected or produces a bad signal, then "99" is di

he left decimal point blinks left in the rhythm of 0.25 seconds (no cross‐fadi

he right decimal point of the right tube remains unchanged in its function. 

splayed and the minus sign or 

ng).  

t

T
 

7  Special Notes on the IN-16 tubes 

There are several variants of the IN‐16 tubes. One has a hole with Ø 4 mm in the spacer, the other has not. 

Here you can see this difference: 
 

 

With hole: 

 

 

 

 

without hole 

               

 

 

f you fit any under body lighting tubes, this difference is not important to you. However, if you install an 

I

under body lighting, you have to refer to the following. 
 

If you use the version with a hole in the spacer, there is no need to change anything, because the LED 
exactly fits into this hole.  

But if you use the version without the hole, then you have to drill a hole of Ø4, 5 mm into the middle of the 

spacer. To do so, slide away the spacer from the tube and drill the hole. 

Note:

 

From

 

Nocrotec

 

you

 

get

 

matched

 

tube

 

sets

 

WITH

 

hole

 

in

 

spacer

 

for

 

the

 

LEDs

 

(

HERE

)

 

Summary of Contents for Temp n Glow IN-16

Page 1: ...e art too A smart menu system makes operation easy Adjustable change interval error detection and many other features are standard on Temp n Glow A high to go light is the so called Cathode Poisoning...

Page 2: ...6 Error indication 6 7 Special Notes on the IN 16 tubes 6 8 Part List 8 9 Soldering 9 10 Mounting of the Neon glow lamp 10 11 Solder the tubes 11 12 Solder the Leds 12 13 Switching off the underside L...

Page 3: ...ject and liquid entry Care should be taken so that the thermometer does not fall into liquids them spilled over the thermometer Do not use this appliance for anything other than the intended use as de...

Page 4: ...F no adjustment nece measuring range from 55 C to 85 C 67 F to 99 Display in C or F Long cables available for external sensor up to 10 m Pre assembled temperature sensor cable available from web shop...

Page 5: ...equently ll settings are described A a 4 Settings 1 change interval reby the value of x is the range 1 9 in seconds nside outside or only one of them is updated at a range of 1 9 seconds The display s...

Page 6: ...ure is below 99 or over 99 C or F the display still shows 99 to 99 6 Error indication If one of the sensor is not connected or produces a bad signal then 99 is di he left decimal point blinks left in...

Page 7: ...e tubes holes in the spacer After you have drilled you need to connect the tube wires through the his can easily be done by a spiral staircase cut of the wires hen the threading into the spacer and th...

Page 8: ...Temperature sensor with cable 1 meter L1 1 Coil 330 H 1 4 A R10 R11 2 Resistor 180 Ohm R20 1 Resistor 390 Ohm R30 R31 2 Resistor 2 2k R32 R33 2 Resistor 4 7k R38 1 Resistor 8 2k R40 R43 4 Resistor 16k...

Page 9: ...tch ut for the marking that you find on the IC and on the pcb Then L1 the capacitors the resonator CR1 and he coil are soldered in The resonator has no polarity o t Figure 1 resistor and diodes mounte...

Page 10: ...t g p 10 Mounting of the Neon glow lamp Cut fuse holder tab ts ter 1mm Cut the fuse holder contac ire diame Stretch silver w Solder wire from the rear Bend the wires Pull 2 pieces of shrinking tube 21...

Page 11: ...be sure that the tube is soldered correctly into the board it is important to know where the anode is Figure 4 The step cut The anode is marked white and you find it at the back of the tube You can s...

Page 12: ...oles hold wires after the tube has been mounted No hole is free lign the tubes rectangular You should first solder only two wires and check the angle Now solder the est of the wires and cut he rest no...

Page 13: ...underside LED illumination The Leds illuminate the underside of the board creating a beautiful effect in a n acrylic enclosure at night f you do not want the effect you can easily switch that off With...

Page 14: ...cable length of 10 meters Please only use the cables from the shop Otherwise you might get disturbances in the capacity of the cable data transfer or short cables 1 meter you can use your own 2 pin f...

Page 15: ...A Maximum input voltage 14 V m Maximum input current at 12 V 150 12V 1 8 W Maximum input power at Measuring range 55 C to 99 C e of 10 C to 85 C Range 67 F to 99 F g Tolerance 0 5 C in the ran Overall...