Nixie NixieTherm Mk II Assembly And Mounting Instructions Download Page 1

Aufbau- und Montageanleitung NixieT

NixieT

NixieT

NixieT

NixieTher

her

her

her

herm Mk II 

m Mk II 

m Mk II 

m Mk II 

m Mk II T

T

T

T

Ther

her

her

her

hermometer

mometer

mometer

mometer

mometer

Assembly- and Mounting-Instructions NixieT

NixieT

NixieT

NixieT

NixieTher

her

her

her

herm Mk II ther

m Mk II ther

m Mk II ther

m Mk II ther

m Mk II thermometer

mometer

mometer

mometer

mometer

– 1 / 8 –

Herzlichen Glückwunsch zum Erwerb Ihres NixieTherm Mk II Thermometer Bausatzes.
Um Erfolg beim Zusammenbau garantieren, ist die Beachtung einiger Grundregeln unbe-
dingt erforderlich.

• Dieser Bausatz richtet sich an den fortgeschrittenen Bastler. Erfahrungen in der Elektronik
sind hierbei unerlässlich.
• Wenn Sie merken, dass der Bausatz für Sie zu kompliziert ist, versuchen Sie bitte nicht, ihn
„zusammenzuschustern“. Dies endet in der Regel in einem nicht mehr reparablen Gerät. Bitte
wenden Sie sich so früh wie möglich an den Anbieter, der Ihnen Hilfestellung geben kann.
• Bitte nehmen Sie mindestens 1-2 Stunden Zeit. Einen Bausatz in Hektik zusammenzulöten,
erzeugt letztendlich nur Frust – und die Fehlersuche dauert hinterher „ewig“.
• Ihr Arbeitsplatz sollte sauber, aufgeräumt und gut ausgeleuchtet sein.
• Entsprechendes Elektronikerwerkzeug wie Schraubendrehersatz, Seidenschneider, Spitz-
zange und Pinzette sollte sich in Griffnähe befinden.
• Nur eine temperaturgeregelte Elektronik-Lötstation mit max. 1 mm runder Spitze samt ent-
sprechendem bleifreien dünnem Lötzinn verwenden; sehr gute Erfahrung wurde mit Lötzinn
Iso-Core EL Sn95,5 Ag3,8 Cu0,7 mit 0,5 mm Ø und 3,5% Flussmittel von Felder Löttechnik und
400°C Löttemperatur gemacht.
• Für den Funktionstest benötigen Sie ein Multimeter mit einem Messbereich von 200 V.
• Eine Lupe für das Lesen der Bauteilebedruckungen ist ganz hilfreich.
• Bitte halten Sie sich beim Bestücken an die in dieser Anleitung vorgegebene Reihenfolge.
Diese ist erprobt und vermindert auch das Fehlerrisiko.
• Es wird davon ausgegangen, dass Ihnen bekannt ist, dass Halbleiter (Dioden, IC’s, Transis-
toren) oder Elkos gepolte Bauelemente sind, eine entsprechende Markierung besitzen und
deshalb auch in der korrekten Richtung bestückt werden müssen.

Zusammen mit dieser Bauanleitung erhalten Sie weitere hilfreiche Dokumente:

• Das komplette Schaltbild des NixieTherm Mk II Thermometers in Farbe.
• Die vollständige Stückliste mit Farbcodes der Widerstände.
• Eine zweisprachige Bedienungsanleitung für Ihr NixieTherm Mk II.

Wichtige Sicherheitshinweise:

Beim Aufbau, der Inbetriebnahme sowie bei Messungen und Reparaturen ist besondere Vor-
sicht geboten! Die im Thermometer erzeugte Hochspannung von ca. 127 V kann gefährlich
sein. Der Aufbau der Schaltung geschieht auf eigene Gefahr. Die Funktionstüchtigkeit kann
nicht garantiert werden, ebenso wenig die Eignung für bestimmte Einsatzzwecke. Der An-
wender hat diese Eignung selbst zu überprüfen und zu verantworten. Für Schäden, die wäh-
rend oder als Folge des Aufbaus oder Betriebs entstehen, kann keine Haftung übernommen
werden, insbesondere für Schäden, die aus mangelnder Fachkenntnis heraus entstehen.
Das Thermometer darf nur in einem berührungssicheren Gehäuse in trockenen Innenräumen
betrieben werden. Derjenige, der einen Bausatz fertig gestellt oder eine Baugruppe durch
Erweiterung bzw. Gehäuseeinbau betriebsbereit gemacht hat, gilt nach VDE 0869 als Herstel-
ler und ist verpflichtet, bei der Weitergabe des Geräts alle Begleitpapiere mitzuliefern und auch
seinen Namen nebst Anschrift anzugeben. Geräte, die aus Bausätzen selbst zusammenge-
stellt werden, sind sicherheitstechnisch wie ein industrielles Produkt zu betrachten.

Und nun, meine Dame, mein Herr – befeuern Sie Ihre Lötstation und blättern Sie um...

Congratulations for purchasing this stunning thermometer NixieTherm Mk II.
For successful assembly of the this kit please read the following helpful hints.

• This kit is designed for someone who has advanced experience with assembling electronics.
• If you believe that the kit is too complicated for your skill level please do not try to assemble it
- this generally ends up with a device that is not repairable and results in you being very
frustrated. Please contact the provider and they can offer you other options that will end in a
more fulfilling result!
• Take your time - this kit should take 1-2 hours to complete if uninterrupted.  Assembling the kit
in a hurry will lead to frustration and the troubleshooting takes three times as long.
• Ensure your work area is well lit (daylight preferred) and clean.
• Electronic tools, such as pliers, small side-cutters or tweezers should be handy. You will also
need a T8 (Torx) or SW2 Allen screwdriver for the housing assembly.
• A soldering iron station with a 1 mm round tip (maximum) and a 0.8 mm (maximum) fine
electronic solder (lead-free) is required. For lead-free solder good experience was made with
type Iso-Core EL Sn95,5 Ag3,8 Cu0,7 with 0,5 mm Ø and 3,5% Flux from Felder Löttechnik an
400°C soldering tip temperature.
• For the intermediary function test you need a multimeter with at least 200 VDC range.
• A loupe to read the small device markings is often helpful.
• Assemble the board in the order as stated in the instructions - this has been proven and will
minimize mistakes.
• It is assumed that you understand that semiconductors (diodes, ICs, transistors) or electrolytic
capacitors are polarized components. Appropriate markings are silk-screened on the PCB and
shown on the board schematic.

Together with this construction guide you get some additional helpful documents:

• The full colour schematic of the NixieTherm Mk II
• A full part list with the colour coding of the resistors
• A bilingual operation manual is encluded to the NixieTherm Mk II kit.

Safety precautions:

During assembly, operation, measurements and maintenance extra precautions must be taken.
The generated high voltage of 127V is dangerous.
Assemble the circuit at your own risk.
The functionality cannot be guaranteed when assembled by the customer.
No responsibility can be taken for any personal claims and damages during assembly and
commission, especially for damages based on insufficient technical knowledge.

The NixieTherm thermometer may only be operated in a solid and moisture-proof enclosure.

The person who completes the kit and assembles this board into an enclosure for operation is
considered by the German directive VDE 0869 as a manufacturer and is required to indicate
their name and address including all documents when selling the thermometer.
Ready-to-go devices, which are assembled from kits, are counted safety-related as an industrial
made product.

Okay, and now, Ladies and Gentlemen – start your soldering irons and flip the page...

Summary of Contents for NixieTherm Mk II

Page 1: ...augruppe durch Erweiterung bzw Geh useeinbau betriebsbereit gemacht hat gilt nach VDE 0869 als Herstel ler und ist verpflichtet bei der Weitergabe des Ger ts alle Begleitpapiere mitzuliefern und auch...

Page 2: ...h unten ab Setzen Sie jetzt den Transistor in die drei runden Pads direkt oberhalb von T2 ein und drehen die Leiterplatte um Der Transistor wird sich dadurch selbst rich tig ausrichten bitte jedoch ko...

Page 3: ...s Zum Schluss setzen wir noch die drei IC s in ihre Fassungen ein Damit ist die Best ckung der Leiterplatte beendet und wir kommen zum ersten Funktionstest Bitte berpr fen Sie vorher trotzdem noch ein...

Page 4: ...lose die Achse auf TR2 auf und gleichen die Spannung an Testpunkt UREF auf 4 0V ein Ziehen Sie danach die Achse wieder ab Damit ist die Pr fung und der Abgleich unserer Elektronik beendet und wir begi...

Page 5: ...m ssen die Klammern auch so einge setzt werden dass die Nut hinten ist Spannen Sie die Skala so best ckt vorsichtig jetzt Kopfstand in Ihren Schraubstock ein d h das Skala steht auf dem Kopf und die...

Page 6: ...nrahmen H lften entfernen die Schutzfolien und st lpen diese von oben ohne zu verkanten ber zwei herausschauenden Distanzen Danach setzen Sie den n chsten Zwischenrahmen mit der Kammer auf Achten Sie...

Page 7: ...r R hre beim Hindurchsehen erkennen Weiterhin darf nur der linke Trimmer TR2 durch die Bohrung im Boden erreichbar sein Sehen Sie auch hierzu auf das Bild auf der Folgeseite Ziehen Sie bitte die vier...

Page 8: ...s ei nes PC s oder Laptop garantiert werden Am Sichersten betreiben Sie das NixieTherm an einem ei genen 5V 500mA Netzteil USB Lader Congratulations Now have a lot of fun with your self assembled Nixi...

Page 9: ...1 6 2 2 350V C14 1 3 470 F 10V LowESR C15 1 4 Kodensatoren Capacitors 100 F C1 C2 C3 C4 C5 C6 C7 C8 C10 C11 C16 11 Schiebeschalter Slide switch S1 1 EMV Drossel EMV Inductor L1 1 47 H Drossel Inductor...

Page 10: ...H L2 47uH LED5 RGB LED5 RGB C19 330p C19 330p R18 2k49 R18 2k49 OUT VS GND IC1 LM35 OUT VS GND IC1 LM35 A A C5 100 C5 100 Utemp Utemp R7 2k49 R7 2k49 LED6 RGB LED6 RGB R4 1k R4 1k C17 100nK C17 100nK...

Reviews: