Instruction manual
OCM Pro CF
®
OCM Pro CF - Rev. 09 as of 07.06.2016
page 21
Fig. 6-2
Possible combinations OCP type M4
Note
A maximum of one air-ultrasonic sensor type OCL or DSM (with EBM) may be
connected to a measurement system.
1
Mounting plate
2
Acoustic coupling layer
3
Temperature sensor
4
Flow velocity sensor
5
Level sensor (optional)
6
Elektronics
7
Pressure sensor (optional)
8
Duct for pressure measurement (optional)
9
Cable gland
Fig. 6-3
Basic design POA wedge sensor