Nivetec Signet 2760 DryLoc Product Manual Download Page 2

2

Signet 2760 DryLoc pH/ORP Preampli

fi

 er

1.  Depressurize and vent system prior to installation or removal.
2. Con

fi

 rm chemical compatibility before use.

3.  Do not exceed maximum temperature/pressure speci

fi

 cations.

4.  Wear safety goggles or faceshield during installation/service.
5.  Do not alter product construction.
6.  When using chemicals or solvents care should be taken and 

appropriate eye, face, hand, body, and/or respiratory protection 
should be used.

WARNING

The retaining nuts of certain pH and ORP sensors and 
preampli

fi

 ers are not designed for prolonged contact 

with aggressive substances. Strong acids, caustic 

substances and solvents or their vapor may lead to failure of 
the retaining nut, ejection of the sensor and loss of the process 

fl

 uid with possibly serious consequences, such as damage to 

equipment and serious personal injury. Retaining nuts that may 
have been in contact with such substances, e.g. due to leakage 
or spilling, must be replaced.

Caution / Warning / Danger

Indicates a potential hazard. Failure to follow all warnings 
may lead to equipment damage, injury, or death

Electrostatic Discharge (ESD) / Electrocution Danger

Alerts user to risk of potential damage to product by ESD, 
and/or risk of potential of injury or death via electrocution.

Personal Protective Equipment (PPE)

Always utilize the most appropriate PPE during 
installation and service of Signet products.

Pressurized System Warning

Sensor may be under pressure, take caution to vent 
system prior to installation or removal. Failure to do so 
may result in equipment damage and/or serious injury.

Hand Tighten Only

Overtightening may permanently damage product threads 
and lead to failure of the retaining nut.

Do Not Use Tools

Use of tool(s) may damage product beyond repair and 
potentially void product warranty.

Refer to your local Georg Fischer Sales of

fi

 ce for the most 

current warranty statement.

All warranty and non-warranty repairs being returned must 
include a fully completed Service Form and goods must be 
returned to your local GF Sales of

fi

 ce or distributor. 

Product returned without a Service Form may not be 
warranty replaced or repaired.

Signet products with limited shelf-life (e.g. pH, ORP, chlorine 
electrodes, calibration solutions; e.g. pH buffers, turbidity 
standards or other solutions) are warranted out of box but not 
warranted against any damage, due to process or application 
failures (e.g. high temperature, chemical poisoning, dry-out) or 
mishandling (e.g. broken glass, damaged membrane, freezing 
and/or extreme temperatures).

Thank you for purchasing the Signet line of Georg Fischer 
measurement products.
If you would like to register your product(s), you can now 
register online in one of the following ways:
 •  

Visit our website 

www.gfsignet.com. 

Under 

Service and Support

 click on 

Product Registration Form

  •  If this is a pdf manual (digital copy), 

click here

Chemical Compatibility

Warranty Information

Product Registration

Safety Information

General

Compatible Electrodes
Signet DryLoc Electrodes .....  2724-2726, 2756-WTP- 2757-WTP, 

2764-2767, 2774-2777

Compatible Instruments
 Preampli

fi

 er models to

  Signet 5700, 8750 ............. 2760-1, -2, -11, -21

Response Time (includes response time of electrodes):
  pH ..................................... < 6 sec. for 95% of change 
 ORP 

.................................. application 

dependent

 Temperature, 

τ

 .................. 20 sec.

Electrical (2760-1, -2,-11, -21 Preampli

fi

 ers)

Maximum Offset ................... ± 7 mV
Input Impedance, Z............... > 1011 

Ω

Supply Voltage (V+ to V–) .... 6 to 12 VDC
Current consumption ............ < 1 mA

Environmental

Enclosure Rating .................. 2760-1, -2, NEMA 6P/IP68

2760-11, -21, NEMA 4
with electrode and watertight
conduit and/or extension pipe
connected

Materials
  Submersible versions........ CPVC (Gray)
  In-Line versions................. PBT (Yellow)

Cable .................................... 4.6 m (15 ft) 6-conductor 

w/shield, 22 AWG

Maximum cable: ................... 122 m (400 ft)
Shipping Weight: .................. 0.64 kg (1.41 lb)

Operating Temperature ......... 0 °C to 85 °C (32 °F to 185 °F)
Storage Temperature ............ –20 °C to 85 °C (–4 °F to 185 °F)
Relative Humidity.................. 0 to 95%, non-condensing

(without electrode connected)

Standards and Approvals

Manufactured under ISO 9001 and ISO 14001
  China RoHS (Go to www.gfsignet.com for details)

Speci

fi

 cations

Summary of Contents for Signet 2760 DryLoc

Page 1: ...H and ORP electrodes to supply an amplified mV analog signal to Signet instruments 3 2760 090 3 2760 090 Rev 9 01 18 Description Table of Contents English Deutsch Français Español Product Manual Warranty Statement 2 Product Registration 2 Safety Information 2 Chemical Compatibility 2 Specifications 2 Dimensions 3 In Line Assembly and Installation 3 4 Wet Tap Assembly and Installation 4 Submersible...

Page 2: ...on warranty repairs being returned must include a fully completed Service Form and goods must be returned to your local GF Sales office or distributor Product returned without a Service Form may not be warranty replaced or repaired Signet products with limited shelf life e g pH ORP chlorine electrodes calibration solutions e g pH buffers turbidity standards or other solutions are warranted out of ...

Page 3: ...ocked When fully assembled the 2760 will stand about 100 mm 4 in above the installation fitting Lock Unlock 100 mm 4 in Lubricate O rings 1 2 3 4 5 2760 In Line models used with 2764 2767 or 2774 2777 series electrodes BEFORE YOU START 2764 2767 Install a 1 in NPT pipe tee into the process line 2774 2777 Install a in reducing tee into the process line 1 Wrap the process threads on the electrode wi...

Page 4: ... tee in the process line DO NOT install in a inch tee or probe will be damaged 1 Wrap the process threads on the electrode with an appropriate sealant example PTFE tape to create a water tight connection 2 Lubricate O rings with a non petroleum based viscous lubricant grease compatible with the system 3 Remove the threaded nut from the preamplifier and place it around the electrode from the bottom...

Page 5: ...ier dry and clean at all times 3 Attach 3 4 in watertight pipe to the top of the 2760 Secure the threaded connection to prevent any leakage Fill the lower 75 100 mm 3 to 4 in of conduit or extension pipe with a flexible sealant such as silicone to prevent liquid accumulation on the back seal of the 2760 OR OR The submersible 2760 can be installed in a tank or vessel if conditions are within pressu...

Page 6: ...mV Input Brown wire Brown mV 4 20 mA Red V Black V White T Green T Connect this terminal to Earth GND to reduce electrical interference White Temp Green Temp Blue Iso Gnd Brown mV input Shield Black V Red V 12 11 10 9 8 7 6 5 18 17 16 15 14 13 12 11 16 15 14 13 12 11 10 9 3 8750 1 3 8750 2 3 8750 3 ProcessPro pH ORP Transmitter 3 2760 11 3 2760 21 Any of these electrodes can be connected to the Si...

Page 7: ...le 3 2760 1 3 2760 2 DryLoc Preamplifier In Line 3 2760 11 3 2760 21 White Temperature Green Temperature Blue mV Reference Shield Earth Ground Black V Red V Brown Active mV pH ORP Signet Combination pH Electrodes 3 2724 10 3 KΩ NPT 3 2724 11 3 KΩ ISO 3 2726 10 3 KΩ NPT 3 2726 11 3 KΩ ISO 3 2726 HF 10 HF Resist 3 KΩ NPT 3 2726 HF 11 HF Resist 3 KΩ ISO 3 2726 LC 10 Low Cond 3 KΩ NPT 3 2726 LC 11 Low...

Page 8: ...ings 3 2726 10 159 001 555 Bulb glass pH Electrode 3 KΩ RTD in NPT or Signet fittings 3 2726 11 159 001 556 Bulb glass pH Electrode 3 KΩ RTD ISO 7 1 R or Signet fittings 3 2726 HF 10 159 001 551 Bulb glass pH Electrode 3 KΩ RTD HF resistant in NPT or Signet fittings 3 2726 HF 11 159 001 552 Bulb glass pH Electrode 3 KΩ RTD HF resistant ISO 7 1 R or Signet fittings 3 2726 LC 10 159 001 559 Bulb gla...

Reviews: