NIVELCO Nivocap CK User Manual Download Page 2

2/3 

 

ckm105en2106h

 

2.5

 

O

RDER CODES

 

(

NOT ALL COMBINATIONS ARE POSSIBLE

!)

 

 

2.6 D

IMENSIONS

 

Standard 

With Extension Rod 

With Extension Cable 

High-temperature version  

with standard probe 

High-temperature version 

with rod probe extension 

CKM–1



–1, CKP–1



–1

 

CKR–1



–1, CKL–1



–1

 

CKK–1



–1, CKC–1



–1

 

CMM–1



–1, CMP–1



–1

 

CMR–1



–1, CML–1



–1

 

 

 

 

 

 

3. MOUNTING 

It is advised to check if the device is working properly on a sample quantity of material before installing the device. 

WARNING! 

• Handle the device with great care, with special attention to the probe. Any strong impact or bending to the probe may damage the device. 

• 

A protective shield must be installed (see the figure) if the probe is exposed to falling material or excessive mechanical load. 

• 

For tanks where strong vibration may occur, use the vibration-resistant version with the solid-state switch 

(see sections 2.4 and 2.5!)

• 

The device is rated IP67 - in the case of liquids, only the lower metal part of the probe may touch the liquid continuously! 

Screw in the device by its hexagonal neck. After screwing process connection in tightly, the housing can be rotated (max. 300°), to adjust the cable gland to the required position.

 

It might become necessary to install the device at an offset level position relative 
to the switching level taking the coning and caving of the material in the silo into 
account.

 

 

 

 

High level indication 

Low level indication

 

 

In the case of powders, the angle of the side-mounted device's probe must be greater than 
that of the coning of the medium (or, in the case of high-level detection, vertical) to prevent 
powder deposition on the probe that might cause false switching. Avoid mounting the unit 
near recesses any surface that facilitates forming deposits. 

 

 

 Recommended 

Not 

recommended 

 

 

 

N I V O C A P   C         -         -   

Ex

(*) 

                                        

 

 

     

 

     

 

   

 

 

 

 

 

 

 

 

     

 

     

 

 

 

 

 

 

 

 

 

     

 

     

 

     

 

 

   

 

   

 

 

V

ERSION

 

C

ODE

 

 

P

ROBE 

T

YPE

 

C

ODE

 

 

H

OUSING

 

C

ODE

 

 

P

ROBE 

L

ENGTH 

[m (ft)] 

  O

UTPUT 

/

 

E

X

 

C

ODE

 

Standard 

 

Standard ¾" BSP 

 

Aluminum 

 

C

ODE

 

 

C

ODE

 

 

 SPDT, potential-free relay 

High-temp . 

 

Standard ¾" NPT 

   

 

 

0 (0) 

0 (0) 

  SPST, solid-state output  

 

 

 

Standard / 1" BSP 

 

 

 

 

1 (3.3) 

0.1 (0.33) 

 

SPDT, potential-free relay / Ex ta/tb IIIC 

Standard / 1" NPT 

P 2 

2 (6.6) 

0.2 (0.66) 

SPST, solid-state output / Ex ta/tb IIIC 

 

 

 

Standard / 1½" BSP 

 

 

 

 

3 (10) 

0.3 (1) 

 

 

 

Standard / 1½" NPT 

N 4 

4 (13) 

0.4 (1.3) 

 

 

 

 

 

With extension rod / 1½" BSP 

 

 

 

 

5 (16.3) 

0.5 (1.63)     

 

 

 

 

With extension rod / 1½" NPT 

 

 

 

 

6 (19.7) 

0.6 (1.67)     

 

 

 

 

With extension cable / 1½" BSP 

 

 

 

 

7 (23) 

0.7 (2.3)     

 

 

 

 

With extension cable / 1½" NPT 

 

 

 

 

8 (26) 

0.8 (2.6)     

 

 

 

 

With extension rod ¾" BSP 

 

 

 

 

9 (29.5) 

0.9 (2.95)     

 

 

 

 

With extension rod ¾" NPT 

 

 

 

 

10 (33) 

 

 

   

 

 

 

 

With extension rod 1" BSP 

 

 

 

 

 

 

 

 

   

 

 

 

 

With extension rod 1" NPT 

 

 

 

 

(*)

 The order code of an Ex-version should end in ’Ex’ 

 

 

 

 

 

 

 

 

 

 

Variants with extension cable types: from 1 m up to 10 m (3.3…33 ft) , by 0.5 m (1.64 ft) steps! 

 

 

 

 

 

 

 

 

 

 

Variants with extension rod types: from 0.7 m up to 3 m (2.3…10 ft), by 0.1 m (0.32 ft) steps! 

 

 

 

 

 

 

 

 

 

 

Standard types : CK

-103, CK

-104, CK

-105, CK

-106 

 