NIVELCO Nivocap CK User Manual Download Page 1

 

 

ckm105en2106h 

 

1/3 

Thank you for choosing a NIVELCO instrument. 

We are convinced that you will be satisfied with our product! 

 

1. APPLICATION 

The 

NIVOCAP CK

 capacitive level switches operate in the RF (radio-frequency) ~ 130 kHz range. 

 

The instrument is less sensitive to material adhesions caused by the measuring probe's design and the so-called reference 
probe-based operating principle. The device is capable of level switching in solids and powders with a dielectric constant 
greater than 1.5 relative permittivity (

Ɛ

r) and to a limited extent in liquids (see 2.1 General data). 

The device needs to be calibrated after it is installed. 

During operation, the device evaluates the capacitance difference of the connected probe continuously. Until the probe is 
in the air (the medium does not reach the probe) the measuring and reference probe is at the minimal capacitance value  
(

ε

relative

=1) relative to the instrument housing. When the medium reaches the probe, the capacitance will increase 

(

ε

relative

1). The device measures the capacitance change relative to the reference value stored during the calibration 

procedure. 
The reference probe is designed so that the material deposits on the probe are ignored, preventing any false switching. 
There are four measuring ranges switchable on the device (see Chapter 4: Sensitivity Ranges) 
4

th

 sensitivity range:  

0.5 pF,  

ε

relative

= 1.5…2.0 

3

rd

 sensitivity range:  

2.5 pF,  

ε

relative

= 2.0…4.0 

2

nd

 sensitivity range:   8.0 pF,  

ε

relative

= 4.0…7.0 

1

st

 sensitivity range:    18 pF,  

ε

relative

= > 7.0 

 

2. TECHNICAL DATA 

2.1

 

G

ENERAL DATA

 

Type 

Standard 

CK(D,G,M,P,H,N)–1



–1 

CM(D,G,M,P,H,N)–1



–1 

With Extension Rod 

CK(R,L,E,F,V,Z)–1



–1, 

CM(R,L,E,F,V,Z)–1



–1 

With Extension Cable 

CKK–1



–1 

CKC–1



–1 

Probe length 

0.3…0.6 m (1.3…2 ft) 

0.7…3 m (2.3…10 ft) 

1…10 m (3.3…33 ft) 

Material of wetted parts 

1.4571 (316Ti) stainless steel + PPS insulation 

1.4571 (316Ti)  

+ PPS Insulation; 

Cable: PE-coating 

Process connection

 

As per order code (see 2.5 Order Codes) 

Ambient temperature 

(1) 

–30…+65 °C (–22…+149 °F) 

Medium temperature 

(1)

  

(for solids) 

–30…+110 °C (

22…+230 °F) 

–25…+80 °C 

(

13…+176 °F) 

Medium temperature for  
high-temperature version

 (1)

  

(for solids) 

–30…+235 °C (

22…+455 °F) 

– 

Medium temperature 

(1)

  

(for liquids) 

0…+65 °C (+32…+149 °F) 

Max. process pressure 

16 bar (1.6 MPa, 232 psi) 

Response time (selectable) 

0.15…15 sec 

Power supply (universal) 

20…250 V AC (50/60 Hz)   or   20…50 V DC 

Power consumption 

 2.5 VA / 2 W 

Housing material 

Powder-coated aluminum 

Electrical connection

 (1) 

2× M20x1.5 plastic cable glands, for cable Ø6…Ø12 mm (.236"… .472"), 

2× terminal blocks for 0.5…1.5 mm² (AWG20…15) wire cross section 

Electrical protection 

Class I. 

Ingress protection 

IP67 

Weight 2

 

kg (4.4 lb) 

2 kg + 1.4 kg/m  
(4.4 lb + 1 lb/ft) 

2 kg + 0.6 kg/m 

(4.4 lb + 0.4 lb/ft) 

(1)

 For explosion-proof design, see section 2.3 Ex information 

 

 

 

2.2

 

ACCESSORIES

 

 

User’s manual, 

 

Warranty Card, 

 

EU Declaration of Conformity, 

 

2× 3-pole terminal blocks, 

 

1 ½ " klingerit sealing, for BSP only 

 

2× M20x1.5 cable glands 

 

 

2.3

 

E

X INFORMATION

 

 

 

C



–1



–5E

X

,

 

C



–1



–7E

X

 

Reference document 

Ex marking 

ATEX 

 II 1/2D Ex ta/tb IIIC T85°C…T220°C Da/Db ckm1051m060bh_06 

IEC Ex 

Ex ta IIIC T85°C…T220°C Da/Db 

ckm1051a0600h_02 

Electrical connection 

 

2× M20×1.5 metal cable glands for Ø8…Ø13 mm (Ø.315… Ø.5") cable 

 

Thermal Properties

 

With extension cable 

Standard, or with extension rod 

CKK–1



–5, 7Ex 

CKC–1



–5, 7Ex 

CK(D,G,M,P,H,N)–1



–5, 7Ex 

CK(R,L,E,F,V,Z)–1



–5, 7Ex 

High-temperature version 

CM(D,G,M,P,H,N)–1



–5, 7Ex 

CM(R,L,E,F,V,Z)–1



–5, 7Ex

 

Medium temperature min.: –30 °C (

22 °F); 

max.: 

+60 °C  

(+140 °F) 

+70 °C  

(+158 °F) 

+80 °C  

(+176 °F) 

+60 °C  

(+140 °F) 

+70 °C  

(+158 °F) 

+95 °C 

(+203 °F) 

+110 °C 

(+230 °F) 

+220 °C (+428 °F) 

Ambient temperature min.: –30 °C (

22 °F); 

max.: 

+65 °C  

(+149 °F) 

+60 °C  

(+140 °F) 

+65 °C (+149 

°F) 

+60 °C  

(+140 °F) 

+60 °C 

(+140 °F) 

+50 °C  

(+140 °F) 

+35 °C (+95 °F) 

Highest permissible surface temperature 
of the process connection 

+80 °C  

(+176 °F) 

+90 °C  

(+194 °F) 

+80 °C  

(+176 °F) 

+90 °C 

(+194 °F) 

+95 °C 

(+203 °F) 

+195 °C (+383 °F) 

Temperature 

classes 

T85°C T85°C T95°C T85°C T85°C T95°C T110°C 

T220°C 

 

2.4

 

O

UTPUT DATA

 

 

Relay 

Solid-state output 

C



–1



–1, C



–1



–5Ex 

C



–1



–3, C



–1



–7Ex 

Output type 

SPDT (potential-free) SPST 

(electronic) 

Output rating 

250 V AC, 8 A, AC 1 

250 V AC, 50 V DC, 1 A 

Output protection 

— 

— 

 

Reviews: