dkc5127a0600p_01 - 2/5
2.2 DK-600 ORDER CODE (N
OT ALL COMBINATIONS POSSIBLE
!)
NIPRESS
D
K
– 6
2 – *
M
EASURING
METHOD
C
ODE
P
ROCESS CONNECTION
C
ODE
R
ANGE
(1)
/
O
VERPRESSURE
[bar]
C
ODE
A
CCURACY
C
ODE
O
UTPUT
/
C
ERTIFICATES
C
ODE
Switch
K
¼”
BSP
A
-1
– 0 / 4
0
0.5
%
2
1 PNP switching output
7
½”
BSP
C
0
– 0.4 / 1
3
2 PNP switching output
9
¼”
NPT
G
0
– 0.6 / 2
4
4…20 mA 2- wire + 1 PNP switching output / Ex ia G
(2)
F
½”
NPT
H
0
– 1 / 2
5
0 – 1.6 / 4
6
0 – 2.5 / 4
7
0
– 4 / 10
8
0
– 6 / 10
9
0 – 10 / 20
A
0
– 16 / 40
B
0 – 25 / 40
C
0
– 40 / 100
D
0
– 60 / 100
E
0
– 100 / 200
F
0
– 160 / 400
G
* Ex versions are marked "Ex" right after the type designation on the label.
0 – 250 / 400
H
(1)
Custom measuring ranges are available, subject to prior agreement.
0 – 400 / 600
J
(2)
Ex versions are available on special request.
0 – 600 / 800
K
2.3 DK-700 ORDER CODE (N
OT ALL COMBINATIONS POSSIBLE
!)
NIPRESS
D
– 7
– *
M
EASURING METHOD
/
T
EMPERATURE
C
ODE
P
ROCESS CONNECTION
C
ODE
R
ANGE
(6)
/
O
VERPRESSURE
[bar]
C
ODE
A
CCURACY
C
ODE
O
UTPUT
/
C
ERTIFICATES
C
ODE
Switch / up to +125°C
(+257°F)
K
½” BSP
(2)
C
-1 – 0 / 5
0
0.25%
(7)
1
1 PNP switching output
7
¾" BSP
D
0
– 0.1 / 0.5
1
0.5 %
2
2 PNP switching output
9
Switch / up to +300°C
(+572°F)
(1)
L
1" BSP
E
0
– 0.16 / 1
R
4…20 mA 2- wire + 1 PNP switching output /
Ex ia G
(8)
F
¾" TriClamp
T
0
– 0.25 / 1
2
1"
TriClamp
L
0
– 0.4 / 2
3
1½"
TriClamp
M
0
– 0.6 / 5
4
2"
TriClamp
N
0
– 1 / 5
5
* Ex versions are marked "Ex" right after the type designation on the label.
DN25 Pipe coupling
(3)
O
0
– 1.6 / 10
6
(1)
Up to +150°C (+302°F) in vacuum
(2)
p
≥
1 bar (14.5 psig)
(3)
DIN 11851 (0.25–40 bar [3.6–580 psig])
(4)
DIN 11851 (0.25–40 bar [3.6–580 psig])
(5)
DIN 11851 (0.25–25 bar [3.6–362.6 psig])
(6)
Custom measuring ranges are available, subject to prior agreement.
(7)
p
≥
0.4 bar (5.8 psig)
(8)
Ex versions are available on special request.
DN40 Pipe coupling
(4)
P
0
– 2.5 / 10
7
DN50 Pipe coupling
(5)
R
0
– 4 / 20
8
VARIVENT
®
DN40/50
V
0
– 6 / 40
9
0
– 10 / 40
A
0
– 16 / 80
B
0
– 25 / 80
C
0
– 40 / 105
D
2.3
D
IMENSIONS
DKC-5
-
DKC-6
-
DKA-5
-
DKA-6
-
DKG-5
-
DKG-6
-
DKH-5
-
DKH-6
-
If nominal pressure p > 400 bar (5800 psig) the length of devices increases by 19 mm (0.75
inch) in case of non-Ex version and by 39 mm (1.5 inches) in case of IS version.
D
C
−
7
-
D
C
−
7
-
D
−
7
-
T
RI
C
LAMP
D
−
7
-
H
YGIENIC
CONNECTIONS
(P
IPE COUPLING
)
Size
¾”
1”
1
½”
2”
Size
DN 25
DN 40
DN 50
A
[mm] 14 23 32 45
A
[mm] 23 32
45
B
[mm] 25 50.5 50.5 64
B
[mm] 44 56 68,5
P
[bar]
≥
4
/
≤
8
≥
0.25
/
≤
16
≤
16
≤
16
C
[mm] 10
10
11
P
[bar]
≥
0.25
/
≤
40
≥
0.25
/
≤
40
≥
0.25
/
≤
25