NIVELCO NIPRESS DK-300 Installation And Programming Manual Download Page 20

 

dkc3127a0600p_01 - 20/20 

6. TROUBLESHOOTING 

Fault 

Possible causes 

Fault detection / remedy 

No output signal: 

Connected incorrectly. 

Check the connections! 

Conductor/wire breakage.

 

Check all wires with cable tester! 

Defective measuring device (signal input). 

Check the ampere meter (and its fuse) and the analogue input of the signal processing unit! 

 

 

 

Analog output signal too low: 

Load resistance too high. 

Check the value of the load resistance! 

Supply voltage too low. 

Check the power supply and power / current on the transducer / transmitter! 

 

 

 

Slight shift of the output signal: 

The diaphragm of the sensor is severely 
contaminated. 

Cleaning with non-aggressive cleaning solutions, soft brush or sponge. 

The diaphragm of the sensor is calcified or crusted.  It is recommended to clean carefully and remove dirt. 

 

 

 

Large shift of the output signal: 

The diaphragm of the sensor is damaged (caused 
by overpressure or mechanically). 

Check the diaphragm of the sensor, if it is damaged then send the device back to the 
manufacturer! 

7. MAINTENANCE AND REPAIR 

The instrument does not require regular maintenance. If necessary possible dirt deposited should be cleaned off. The repair will be carried out at the NIVELCO' premises only. 
When dismantling the device, it must always be done in the depressurized and currentless condition! Check also if the medium has to be drained off before dismantling. 
If necessary, clean the diaphragm carefully with non-aggressive cleaning solution, soft brush or sponge. Wrong cleaning or improper touch may cause irreparable damage on the 
diaphragm. Therefore, never use pointed objects or pressured air for cleaning the diaphragm. 
Before returning your device for repair, it has to be cleaned carefully, neutralize/decontaminate the harmful substances at the media wetted parts. Beside our appropriate form  
(

Returned Equipment Handling Form

) can be downloaded from homepage 

www.nivelco.com

. You should dispatch the device with a declaration of decontamination. In the declaration, 

you have to declare that the decontamination process had been finished, the device is clean and non-harmful and there is no hazardous substance on it. 
 

8. STORAGE CONDITIONS 

Storage temperature:   -40 °C ... +100 °C (-40 °F ... +212 °F)

(1)

  

(1)

At DK-800 with PVDF pressure port the minimum permissible temperature is -30 °C (-22 °F) 

dkc3127a0600p_01 

November 2019  

NIVELCO reserves the right to change technical data without notice. 

Summary of Contents for NIPRESS DK-300

Page 1: ......

Page 2: ...dkc3127a0600p_01 2 20 DK 300 DK 400 DK 800...

Page 3: ...AL CONDITIONS OF SAFE USE 11 4 INSTALLATION 11 4 1 INSTALLATION INSTRUCTION 11 4 2 WIRING 12 4 3 EXAMPLES OF ARRANGEMENTS 14 5 PROGRAMMING 14 5 1 OPERATING INFORMATION 14 5 2 CONFIGURATION 14 5 3 PASS...

Page 4: ...pressure switch with welded stainless steel flush sensor This makes it suitable for numerous applications in various industrial sectors and is also ideal for viscous or pasty media This device is a 2...

Page 5: ...BSP C 0 0 1 0 5 1 0 5 2 2 PNP switching output 9 3 4 BSP 1 D 0 0 16 1 R 4 PNP switching output 3 E 1 4 NPT G 0 0 25 1 2 4 20 mA 2 wire 1 PNP switching output Ex ia F 1 2 NPT H 0 0 4 2 3 0 0 6 5 4 0 1...

Page 6: ...tching output 9 1 BSP E 0 0 16 1 R 4 PNP switching output 7 E 3 4 TriClamp T 0 0 25 1 2 4 20 mA 2 wire 1 PNP F 1 TriClamp L 0 0 4 2 3 switching output Ex ia 1 1 2 TriClamp M 0 0 6 5 4 2 TriClamp N 0 1...

Page 7: ...PNP switching output 7 1 2 BSP C 0 0 4 1 3 2 PNP switching output 9 3 4 BSP 1 D 0 0 6 2 4 4 PNP switching output 2 E 1 4 NPT G 0 1 2 5 4 20 mA 2 wire 1 PNP switching output Ex ia F 1 2 NPT H 0 1 6 4...

Page 8: ...Output 1 PNP switch output 3 or 2 PNP switch output 3 or 4 PNP switch output 4 Analog output optional Power supply Load resistance 4 20 mA output 2 wire 13 V 36 V DC Rmax USupply 13V 0 02 A 4 20 mA o...

Page 9: ...DC Intrinsically safe data Use only with Ex ia certified power supply module Uimax 28 V DC Iimax 93 mA Pimax 660 mW Ci 0 nF Li 0 mH Max switching current 6 70 mA Permissible temperatures for environm...

Page 10: ...KR 4 DIN11851 hygienic connections DKV 4 VARIVENT PN 25 bar DL 4 COOLING ELEMENT 300 C 572 F Size 1 1 2 Size DN 25 DN 40 DN 50 3 3 ACCESSORIES Installation and programming manual Warranty card EU decl...

Page 11: ...ipe wrench Due to electronic noise protection the pressure switch housing is grounded If the grounding of the technology is correct the pressure switch does not require a separate grounding Otherwise...

Page 12: ...on of a device with cable outlet following bending radiuses have to be complied with Cable without ventilation tube static installation 5 fold cable diameter dynamic application 10 fold cable diameter...

Page 13: ...dard 2 m PVC cable without ventilation tube permissible temperature 5 C 70 C 23 F 158 F Supply 1 1 1 white Supply 3 2 3 brown 3 wire Signal only in 3 wire 2 3 2 green Contact 1 4 3 4 grey Contact 2 5...

Page 14: ...and provides information about the menu items The two buttons below the display are used for moving in the menu and setting the parameters Button this button allows you to move forward in the menu sys...

Page 15: ...zero point and EP end point the analogue output can be configured The following example shows how to use these menu items According to this example your device has a measurement range of 0 400 bar So...

Page 16: ...dkc3127a0600p_01 16 20 5 6 STRUCTURE OF THE MENUSYSTEM STRUCTURE OF THE STANDARD 2 AND 3 WIRE AND THE 4 20 mA 2 WIRE EX ia SYSTEM...

Page 17: ...dkc3127a0600p_01 17 20 4 20 mA 3 WIRE ADJUSTABLE...

Page 18: ...e output signal Menu 6 Exceeding message Set On or Off Menu 7 Menu 9 Menu 11 Menu 13 Set switch on points switching outputs S1 S4 Set a power on value for the relevant output S1 S2 S3 S4 outputs from...

Page 19: ...fter entering this menu item Note that any changes you have made so far will be lost so that the password will return to 0005 Menu 38 Load configuration only 4 20 mA 3 wire adjustable Load configurati...

Page 20: ...sary possible dirt deposited should be cleaned off The repair will be carried out at the NIVELCO premises only When dismantling the device it must always be done in the depressurized and currentless c...

Reviews: