NIVELCO NIPRESS DK-300 Installation And Programming Manual Download Page 1

 

Summary of Contents for NIPRESS DK-300

Page 1: ......

Page 2: ...dkc3127a0600p_01 2 20 DK 300 DK 400 DK 800...

Page 3: ...AL CONDITIONS OF SAFE USE 11 4 INSTALLATION 11 4 1 INSTALLATION INSTRUCTION 11 4 2 WIRING 12 4 3 EXAMPLES OF ARRANGEMENTS 14 5 PROGRAMMING 14 5 1 OPERATING INFORMATION 14 5 2 CONFIGURATION 14 5 3 PASS...

Page 4: ...pressure switch with welded stainless steel flush sensor This makes it suitable for numerous applications in various industrial sectors and is also ideal for viscous or pasty media This device is a 2...

Page 5: ...BSP C 0 0 1 0 5 1 0 5 2 2 PNP switching output 9 3 4 BSP 1 D 0 0 16 1 R 4 PNP switching output 3 E 1 4 NPT G 0 0 25 1 2 4 20 mA 2 wire 1 PNP switching output Ex ia F 1 2 NPT H 0 0 4 2 3 0 0 6 5 4 0 1...

Page 6: ...tching output 9 1 BSP E 0 0 16 1 R 4 PNP switching output 7 E 3 4 TriClamp T 0 0 25 1 2 4 20 mA 2 wire 1 PNP F 1 TriClamp L 0 0 4 2 3 switching output Ex ia 1 1 2 TriClamp M 0 0 6 5 4 2 TriClamp N 0 1...

Page 7: ...PNP switching output 7 1 2 BSP C 0 0 4 1 3 2 PNP switching output 9 3 4 BSP 1 D 0 0 6 2 4 4 PNP switching output 2 E 1 4 NPT G 0 1 2 5 4 20 mA 2 wire 1 PNP switching output Ex ia F 1 2 NPT H 0 1 6 4...

Page 8: ...Output 1 PNP switch output 3 or 2 PNP switch output 3 or 4 PNP switch output 4 Analog output optional Power supply Load resistance 4 20 mA output 2 wire 13 V 36 V DC Rmax USupply 13V 0 02 A 4 20 mA o...

Page 9: ...DC Intrinsically safe data Use only with Ex ia certified power supply module Uimax 28 V DC Iimax 93 mA Pimax 660 mW Ci 0 nF Li 0 mH Max switching current 6 70 mA Permissible temperatures for environm...

Page 10: ...KR 4 DIN11851 hygienic connections DKV 4 VARIVENT PN 25 bar DL 4 COOLING ELEMENT 300 C 572 F Size 1 1 2 Size DN 25 DN 40 DN 50 3 3 ACCESSORIES Installation and programming manual Warranty card EU decl...

Page 11: ...ipe wrench Due to electronic noise protection the pressure switch housing is grounded If the grounding of the technology is correct the pressure switch does not require a separate grounding Otherwise...

Page 12: ...on of a device with cable outlet following bending radiuses have to be complied with Cable without ventilation tube static installation 5 fold cable diameter dynamic application 10 fold cable diameter...

Page 13: ...dard 2 m PVC cable without ventilation tube permissible temperature 5 C 70 C 23 F 158 F Supply 1 1 1 white Supply 3 2 3 brown 3 wire Signal only in 3 wire 2 3 2 green Contact 1 4 3 4 grey Contact 2 5...

Page 14: ...and provides information about the menu items The two buttons below the display are used for moving in the menu and setting the parameters Button this button allows you to move forward in the menu sys...

Page 15: ...zero point and EP end point the analogue output can be configured The following example shows how to use these menu items According to this example your device has a measurement range of 0 400 bar So...

Page 16: ...dkc3127a0600p_01 16 20 5 6 STRUCTURE OF THE MENUSYSTEM STRUCTURE OF THE STANDARD 2 AND 3 WIRE AND THE 4 20 mA 2 WIRE EX ia SYSTEM...

Page 17: ...dkc3127a0600p_01 17 20 4 20 mA 3 WIRE ADJUSTABLE...

Page 18: ...e output signal Menu 6 Exceeding message Set On or Off Menu 7 Menu 9 Menu 11 Menu 13 Set switch on points switching outputs S1 S4 Set a power on value for the relevant output S1 S2 S3 S4 outputs from...

Page 19: ...fter entering this menu item Note that any changes you have made so far will be lost so that the password will return to 0005 Menu 38 Load configuration only 4 20 mA 3 wire adjustable Load configurati...

Page 20: ...sary possible dirt deposited should be cleaned off The repair will be carried out at the NIVELCO premises only When dismantling the device it must always be done in the depressurized and currentless c...

Reviews: