background image

 

‚

 The contents of memory are updated by new printing 

except for manual print and erased at power down. 

Terminal arrangement 

 

Signal terminal block 
 

 
 
 
 
 
 
 
 
 
 

*1: In case of synchronization with no-commercial power source, please take off the short 

circuit of A8 and A12. 

*2: Input circuit, or power source output for external receiver. (For external: 100mA max.) 

*3: In case of using external power source for input circuit, please take off the short circuit 

of A9 and B9, and connect external power to B9.

 

● 

Power source terminal block 

 
 
 
 

Wire connection 

● 

Power source connection   

Connection of usual delivery 

 

 
 
 
 

● 

Pulse input circuit 

 
 
 
 
 
 
 

● 

Pulse input connection (Example of CH1) 

(Use the shielded cable)

 

No-contact input 

 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

Contact input 

 

Open-collector input 

 

 

 

 

 

● 

Control input connection 

(Use the shielded cable)

 

Print signal (CH1) 

 

 

 

 
Reset signal       Count inhibit signal 
 
 
 
 
 
 
Total reset signal   
 
 
 
 
 

 

Model 

Model

Remark

PR

Counting printer

2080D

Version symbol

/NM

・・・・・

Add naming option

/SC

・・・・・

Add scaling option

/E

・・・・・

English print

/Z

・・・・・

Another special software option (

is series number)

Additional

specification

(option)

Specification code

・・・・・・・・・・・・・・・・・・・

・・・・・・・・・・・

 

 

◆◆◆◆◆

Matters to be specified at placing of order

◆◆◆◆◆

 

 
1. Model and specification code 
2. Input pulse unit and indication unit. 
 
 

 

No.

Signal Name

No.

Signal Name

B1

A1

Flow  Signal Input CH.1

B2

A2

Flow  Signal Input CH.2

B3

A3

Print Signal Input CH.1

B4

A4

Print Signal Input CH.2

B5

A5

Reset Signal Input

B6

A6

Count Inhibit Signal Input

B7

A7

NC

B8

A8

Pow er Frequency Output  *1

B9

+12

24VDC Input     *3

A9

+12VDC Output                 *2

B10

A10

Input(For Time synchro)

B11

A11

±Input(For Time synchro)

B12

A12

Input(For Time synchro)

0V COMMON

0V COMMON

No.

Signal Name

N
L

FG

GND

Pow er AC85

264V

Synchronizing with power supply frequency. 

Using in12V DC for input circuits. 

Case of non-contact 12V 
pulse flow meter 

Case of non-contact 12V pulse 
signal 

Flow meter 

(CH1) 

PR

The contents given here are subject to change without notice. 

30 Nogamihata, Nobu-Cho, Ayabe, Kyoto 623-0041, JAPAN 
TEL : +81-773-43-1412 
FAX : +81-773-43-1595 
E-mail:[email protected] 
http://www.nittoseiko.co.jp/  

Reviews: