background image

- 9 - 

6. Name of each Part 

 
6-1)  Front view of the press 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
6-2)  Rear view of the press 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

WARNING

 

label

 

Power cable inlet 

Nameplate 

Temperature controller 

Torque limiter ASSY

 

Fuse box 

Upper heat plate 

Lower heat plate 

Start switch 

Pilot lamp 

Pre-setter guide 

Hook 

Fuse nameplate 

Top cover 

Summary of Contents for PolySprint NPS-1210A-1

Page 1: ...in ng g a an nd d C Co oo ol li in ng g P Pr re es ss s N NP PS S 1 12 21 10 0A A 1 1 2 2 OPERATOR S MANUAL Thoroughly read this operator s manual before operating the press To use endless splicing tools safely be sure to hand this manual to the operator or worker TM ...

Page 2: ...mation of Product 6 3 Specification 7 4 Operation Environment 8 5 Storage Environment 8 6 Name of each parts 9 7 Operation Procedure 11 8 Endless Splicing Procedure 13 9 Troubleshooting 17 10 Inspection 18 11 Maintenance 19 12 Warranty and after sales service 20 ...

Page 3: ...e fire electric shock or injury Do not allow the child to handle this machine Keep this machine in the place where child s hand does not reach Failure to do this may cause fire electric shock or injury A person with technical knowledge and skills should always operate maintain and inspect this machine Handling by a person not having technical knowledge may cause fire electric shock or injury Stric...

Page 4: ...cause fire Always use the pre setter of our product Failure to do this may cause fire or electric shock Use of the pre setter made by other product may possibly spoil the safety protection function of the product Use a dry cloth for cleaning this machine Strictly avoid using alcohol benzene thinner or other inflammable solvents Using inflammable solvents may cause fire Impressed voltage is directl...

Page 5: ...g is not attached When the conversion plug is necessary the user must prepare it yourself Never handle this machine or the plug cable etc with your hands wetting Failure to do this may cause electric shock Never use this machine if wetting Failure to do this may cause electric shock or fire Model Plug type Plug illustration NPS 1210A 1 A Type NPS 1210A 2 CEE7 S Type WARNING WARNING WARNING ...

Page 6: ...or electric shock Take a measure to prevent this machine from dropping or falling or do not install or operate the press at an unstable place Failure to do this may cause injury fire or electric shock Carry out the inspection described on page 18 of this manual before operating this machine Failure to do this may cause fire or electric shock Do not use this machine for the endless splicing of belt...

Page 7: ... manual the press and power cable 3 Has screw and nut loosened We make assurance doubly sure on the inspection and shipment of products In the event of any defect or failure if any please contact your local distributor agent in your area or our company 2 2 Confirmation of the nameplate MODEL Press model INPUT Input power supply specification and power consumption S N Serial number 2 3 Press model ...

Page 8: ... requires the finger puncher and pre setter of another sales The pre setter is required for each width belt that is to be made endless spliced 3 2 Main specifications of the Press Model NPS 1210A 1 NPS 1210A 2 Input power supply 100 120V 200 240V 50 60Hz 50 60Hz 800 1200W 800 1200W Fuse 5 2 20mm 10A 250V Preset temperature 45 200 C Outer dimension With the press closed 240 mm wide 332 mm long 180 ...

Page 9: ...ation etc 5 Storage Environment Ambient temperature 5 40 C no dew condensation Ambient humidity 15 85 R H Working place Indoor place without dust and water Atmosphere No inflammable combustible or corrosive gas and steam When not in use store this machine under the above conditions Poor storage condition may cause mechanical disorder this machine and may cause electric shock or fire When not using...

Page 10: ... of the press 6 2 Rear view of the press WARNING label Power cable inlet Nameplate Temperature controller Torque limiter ASSY Fuse box Upper heat plate Lower heat plate Start switch Pilot lamp Pre setter guide Hook Fuse nameplate Top cover ...

Page 11: ... 10 6 3 Temperature controller Present temperature display Preset temperature display Setting buttons Display change button ...

Page 12: ...ay change button two times to return the present temperature display to the original state 7 3 Hold time setting Temperature controller 1 Check that the pilot lamp is off no heating or cooling 2 Push the para display change button four times to indicate E1 on on the present temperature display At this time the preset temperature display indicates the hold time in sec The hold time before shipping ...

Page 13: ...om touching this machine unexpectedly Failure to do this may cause burn on other people 7 5 Discontinue on the way Disconnect the plug if it becomes necessary to discontinue the machine in operation Even if the plug is disconnected in operation preset data of preset temperature and hold time are maintained The machine when discontinued on the way is kept at high temperature Be sure to wear heat re...

Page 14: ... and wear it Failure to do this may cause burn 8 2 Belt setting Figure Photo Description Fig d Fig e 1 Set both ends of the belt punched into finger shape beforehand on the lower pre setter as shown in Fig d Exercise care not to twisting on the way of belt Confirm the front side and the back side of belt before setting Refer to the attached endless condition table Always use the pre setter of our ...

Page 15: ... lower one while mating the marking lines 8 3 Preparation of press Figure Photo Description Temperature controller Start switch Do not touch now Fig h 1 Connect the power plug to the socket Be sure to connect an earth line Failure to do this may cause electric shock 2 Set the preset temperature and hold time on the temperature controller according to sections 7 2 Temperature setting and 7 3 Hold t...

Page 16: ...e off the pre setter 3 Set the hook and turn the rotary handle until it slips as shown in Fig j Excessive turning will cause the handle to slip in removing also disturbing easy removing 4 Push the start switch to start endless splicing It takes about 60 min to finish one cycle of operation heating temperature holding and cooling with the presetting before shipping at 23 C of environmental temperat...

Page 17: ...n repeat the procedure of section 8 4 Endless splicing Be sure to wear heat resistant gloves when operating the press 8 To end operation check that cooling is completed Then set the hook and turn the rotary handle to lock before disconnecting the power plug as shown in Fig k Securely clamp the hook and rotary handle Insufficient clamping may cause injury WARNING WARNING ...

Page 18: ... sec or more Other than the above Failure of the temperature controller If setting is not possible even by the above controlling failure on the temperature controller is suspected Please contact your local distributor agent in your area or our company Can not be heated to the set temperature The power supply is not same as the specification Yes Impress the suitable power supply No Failure of the t...

Page 19: ...ler is not damaged There is no screw or part missing The machine body is not damaged Heat plates have no resin or foreign matter adhered The pre setter have no flaw The pre setter have no resin or foreign matter adhered The hook or torque limiter have no distortion Please make copies of this page and use them for daily check before use ...

Page 20: ...he pressure parts Lightly apply the grease periodically to the point shown below through This will deliver a correct pressure However please do not apply excessively screw boss of the screw boss of torque limiter sliding part of metal plate ...

Page 21: ...ions environment handling and usage which are not described in the Operation Manual and the Endless Splicing Procedure Malfunction due to a cause arising from something other than the product such as your own device Malfunction arising from any remodeling or repairing by other than our own company Malfunction arising from any reasons unpredictable due to our level of chemistry and technology befor...

Page 22: ... 21 Oct 2020 Rev2 NPS 1210A E ...